background image

 Page 

5

 of 

1

5

DAFU-IOM—01

For basic unit specification

,

 kindly refer to the data on the nameplate affixed outside the unit like the represented figure above which 

will provide 

the 

following unit specifications

:

1) Manufacturer’s name and address
2) Size and serial number of the unit
3) Date of manufacture
4) Nominal Air flow
5) Main supply voltage
6) Frequency
7) Number of phases
8) Motor Power & FLA 

Further information

,

 relative to both construction and performance

,

 

is

 given in the specific product catalogue and technical features

,

 

which is part of this manual.

USE OF THE UNIT

DAIKIN AIR FILTRATION UNIT 

is

 used to remove impurities in air in Residential, Commercial, and Industrial environments.

INSTALLATION

The user/ installer is responsible for ensuring that the unit is installed 

to guarantee

 the static and dynamic stability of the same. All works must 

be carried out in compliance with national legislation on safety in the workplace.

The user

 or 

installer must ensure that atmospheric conditions cannot prejudice the safety of persons or property during installation

 or 

use.

Daikin shall accept no liability whatsoever in the following cases:

Incorrect installation or installation not carried out according to the procedures, partial or total failure to comply with the 

instructions
Incorrect electricity / hydraulic / compressed air supply
Incorrect use of the unit

Lack of maintenance

Unauthorised modifications or repairs

Use of non-original or unsuitable spare parts

QUALIFICATION REQUIRED FOR THE USE AND MAINTENANCE OF THE UNIT

GENERAL OPERATOR

Authorised 

to operate the unit 

through 

the 

s

peed controller and 

s

witches on the unit. 

He/she may only switch the unit on and off and carry out command operations.

B

e fully acquainted with danger and warning signals.

F

ully understand the functioning cycle of the unit, and therefore have carried out theoretical- practical training, operating under 

the direct guidance of an expert operator or user of the unit, or under the direct guidance of one of the manufacturer’s technicians.

MAINTENANCE MECHANIC

Authorised

 to carry out maintenance, regulation, replacement, and repair operations on mechanical 

parts

.

 

He/she 

m

ust be a skilled mechanic and able to carry out mechanical maintenance in a satisfactory and safe manner.

 

Not authorised

 to carry out any operations on the electrical system.

MANUFACTURER’S TECHNICIAN

Authorised

 to carry out complex operations in any situation.

 

He/she works in accordance with the user.

MAINTENANE ELECTRICIAN

Authorised 

to carry out electrical operations for regulation, maintenance, and repairs.

Authorised

to work when voltage is present inside electrical panels and derivation boxes.

He/she must be a skilled electronic/electrical technician, therefore able to carry out.

E

lectrical/electronic maintenance in a satisfactory and safe manner, with theoretical preparation and proven experience.

 

Not authorised

 to carry out mechanical operations.

Содержание DAFU-1000

Страница 1: ...Page 1 of 15 DAFU IOM 01 DAIKIN AIR FILTRATION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL DAFU IOM 01 ORIGINAL INSTRUCTIONS...

Страница 2: ...troduction Guidelines Qualifications Safety Warning Warranty Environmental Conditions Technical Features and Specifications Dimensional Drawing Wiring Diagram Routine Maintenance Non Routine Maintenan...

Страница 3: ...e unloading of the unit Any damage or non conformity with the order must be written on the delivery note and a written complaint must be forwarded to Complaints or contestations sent later than 10 day...

Страница 4: ...RATION UNIT supplied is complete and conforms to the Packing List is delivered together with Installation Operation and Maintenance Manual DAIKIN MIDDLE EAST AFRICA FZE P O BOX 18674 JEBEL ALI FREE ZO...

Страница 5: ...he unit Lack of maintenance Unauthorised modifications or repairs Use of non original or unsuitable spare parts QUALIFICATION REQUIRED FOR THE USE AND MAINTENANCE OF THE UNIT GENERAL OPERATOR Authoris...

Страница 6: ...Every operation on the system or on the electrical appliances must be carried out only by a Qualified Maintenance Electrician Always switch off voltage to the electrical panel before opening the elect...

Страница 7: ...on the part of the operators failure to respect the installation use and maintenance instructions given in this manual or failure to comply with the safety rulings in force for the protection of the...

Страница 8: ...outdoor air changes ACH The air filtration unit can be operated in any of the following modes 1 100 Exhaust 2 100 Recirculating This powerful unit is equipped with an EC Fan that has variable speed co...

Страница 9: ...with activated carbon media Minimum efficiency reporting value MERV 7 UL Classified UV Lamp High output UV lamp 254 nm to inactivate virus bacteria and fungi AstroCel III HEPA filters H14 HEPA Filters...

Страница 10: ...Page 10 of 15 DAFU IOM 01 DIMENSIONAL DRAWING ELECTRICAL WIRING...

Страница 11: ...not running and spinning Check for any damaged or broken cables Ensure that casters are locked properly and tightly Figure 3 If the HEPA filter is clogged then the red light will switch on meaning th...

Страница 12: ...a frame to avoid damage MERV8 PRE Filter Usually the pre filter is installed in the lower position and is recommended to be changed every 2 3 months or as required for better performance For checking...

Страница 13: ...move upward and filter can be easily slide out Figure 7 6 5 Examine the filter frame and filter cabin for any contamination moisture or any dust particles Clean with dry cloth 6 Slide out the contami...

Страница 14: ...s panel properly Check Non Routine Maintenance Section Unusual Sound and Unit Vibration Check if the filters are clogged and replace it if necessary Check Non Routine Maintenance section Dirty Filter...

Страница 15: ...Page 15 of 15 DAFU IOM 01 Africa P O Box 18674 Plot MO0426 JAFZA North Jebel Ali Free Zone Dubai UAE Tel 971 0 4 815 9300 Fax 971 0 4 815 9311 Toll Free 800 DAIKIN 324546 www daikinmea com...

Отзывы: