3 Operation

Operation manual

9

D2CND024A1/4AB + D2TND012~024A4AB
Wall-mounted condensing boiler
3P469438-3M – 2019.11

3.5.3

User settings menu

User settings menu: Parameters (short)

The  user  settings  menu  ( )  comprises  parameters  that  can  be
changed  and  adjusted  by  users.  You  can  read  out  and  adjust  the
parameters according to your preferences.

NOTICE

If you are not sure about the function of the parameter, do
not change it. Contact your service agent.

#

Description

Unit Default Range

U00

Summer-winter switch over
temperature

°C

20

10~30

U01

Heating slope

0

0~40

U02

Central heating ECO mode

0

0~1

U03

Domestic hot water comfort
mode

0

0~1

U04

Domestic hot water set value

°C

50

35~60

U05

Set value for the room
thermostat at day mode

°C

21

10~30

U06

Set value for the room
thermostat at reduced mode

°C

18

10~30

U07

Set value for the flow
temperature at day mode

°C

50

30~80

U08

Set value for the flow
temperature at reduced mode

°C

35

30~80

U09

Domestic hot water comfort
mode user record dependency

1

1, 2 or

24

U10

Room temperature setpoint
used by Daikin room thermostat
during night

°C

18

10~30

t00

(a)

Year

1~99

t01

(a)

Mounth

1~12

t02

(a)

Day

1~31

t03

(a)

Hour

0~23

t04

(a)

Minute

0~59

(a)

Applicable if energy metering is enabled.

User settings menu: Parameters (detailed)

#

Description

U00

When using outdoor sensor, above this parameter
value of outside temperature, the boiler senses the
season as summer and does not activate central
heating although there is demand. Summer-winter
switching has a hysteresis of ±1ºC.

i.e: When this parameter is adjusted to 20ºC, the boiler
switches to summer mode at 21ºC and switches back
to winter mode at 19ºC.

U01

This value is used when only outside sensor is
connected to the boiler (No Opentherm room
thermostat connection). The parameter heating slope is
important to adapt the weather compensation to the
individual heating system, the building and the thermal
insulation. 

The heating slope can be adjusted from 0

to 40. The heating slope needs to be increased to
increase the boiler central heating set temperature.
Colder regions require a higher heating slope value.

Note: 

To activate weather compensation, the heating

slope value must be higher than "5".

U02

Enabling / disabling central heating ECO mode.

1 = enabled, 0 = disabled

#

Description

U03

Enabling / disabling domestic hot water comfort mode.

1 = enabled, 0 = disabled

U04

Domestic hot water set value (same function that can
be done via the right dial when domestic hot water
mode is enabled).

U05

When On-Off room thermostat and outdoor sensor are
both connected, this parameter value is the virtual room
temperature setpoint when there is a heat demand.

U06

When On-Off room thermostat and outdoor sensor are
both connected, this parameter value is the virtual room
temperature setpoint when there is no heat demand.

Note: 

For this parameter value to be active, reducing

mode has to be enabled by your service agent,
otherwise central heating mode will not be activated
when there is no heat demand.

U07

When On-Off room thermostat is connected and
outdoor sensor is not connected, this parameter value
is the central heating water temperature setpoint when
there is a heat demand.

U08

When On-Off Room thermostat is connected and
outdoor sensor is not connected, this parameter value
is the central heating water temperature setpoint when
there is not a heat demand.

Note: 

For this parameter value to be active, reducing

mode has to be enabled by your service agent,
otherwise central heating mode will not be activated
when there is no het demand.

U09

If parameter is 1, comfort mode preheating will depend
on the user record. It will preheat the water according to
the previous day user records.

If parameter is 2, comfort mode preheating will be
independent of the user record, and at the highest
comfort level (3-star comfort according to EN 13302).

If parameter is 24, comfort mode preheating will be
independent of the user record.

Note: 

If you increase the comfort level, the energy

consumption increases.

U10

Room temperature setpoint used by Daikin Opentherm
room thermostat during night mode. Only visible in case
Daikin Opentherm room thermostat is connected.

t00

(a)

t01

(a)

t02

(a)

t03

(a)

t04

(a)

The date and time are set by means of t parameters to
update the LAN adapter. This is needed in case the
LAN adapter does not have internet connection.

Time and date settings is saved when menu is quitted
by pressing (back) button.

After date and time are set, UH-08 error disappears.

(a)

Applicable if energy metering is enabled.

To use the user settings menu

1

Press  the  "Enter"  button  when  the 

  icon  is  displayed  on  the

menu level 1 screen.

Result: 

You can see the parameter values on menu level 2.

2

Select U or t parameters with the left dial.

3

Select the index with the right dial.

4

Press  the  "Enter"  button  when  the  parameter  that  you  want  to
change is displayed.

Result: 

You  can  see  the  menu  level  3  screen.  Up  and  down

arrows will appear.

5

Change the parameter with the right dial.

Содержание D2CND-A1A

Страница 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler D2CND024A1AB D2CND024A4AB D2TND012A4AB D2TND018A4AB D2TND024A4AB ...

Страница 2: ...ndensing boiler that can supply heat to central heating systems as well as supply domestic hot water Depending on settings it is possible to use the unit solely for hot water or solely for central heating Hot water supply type can be instantaneous or by means of a hot water storage tank Heating only boilers do not supply domestic hot water The type of the boiler can be recognised from the model na...

Страница 3: ...ever attempt to perform maintenance or repair yourself Call a qualified service agent CAUTION Do not use sprays solvents chlorinated cleaning agents paint and adhesives in the vicinity of the unit These substances can cause corrosion even in the flue system DANGER Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modificat...

Страница 4: ...show the home screen of the active operation mode and the related setpoint depending on the system configuration see 3 3 3 Possible operation modes 45 Status icons Meaning of icons that appear on the LCD screen Icon Description Operation mode Standby mode Domestic hot water operation enabled Domestic hot water comfort mode is enabled Central heating operation enabled Room temperature Outdoor senso...

Страница 5: ...mode c Summer mode d Winter mode e Full off mode 3 3 3 Possible operation modes Operation mode Description Central heating only mode Only central heating operation mode is enabled The central heating temperature setpoint which setpoint is shown depends on the system configuration see 3 3 5 Possible central heating operation modes 4 6 and the icon is shown on the home screen The icon blinks if cent...

Страница 6: ...oom temperature is displayed The room temperature setpoint can be adjusted from the user interface by means of the left dial or from the Daikin room thermostat The icon is shown on the screen instead of the icon when central heating operation mode is enabled Boiler outdoor sensor Weather compensation The case that outdoor sensor is connected to the boiler In this case the central heating water tem...

Страница 7: ...ion the unit must be connected to the power supply and its main gas valve must be open Any damage caused by frost is not covered by the warranty Frost Protection is enabled in all modes including standby mode and full off mode While frost protection is active Fr and actual flow temperature are displayed subsequently on the display WARNING If the boiler is not connected to the power supply frost pr...

Страница 8: ...l energy consumption Central Heating Last month kWh Description short Unit F12 d Fuel energy consumption Central Heating Current month kWh F13 d Fuel energy consumption Central Heating Current Year kWh F21 d Electric energy consumption Central Heating Last month kWh F22 d Electric energy consumption Central Heating Current month kWh F23 d Electric energy consumption Central Heating Current Year kW...

Страница 9: ...value same function that can be done via the right dial when domestic hot water mode is enabled U05 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there is a heat demand U06 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there i...

Страница 10: ...Do not let your room become too hot Decreasing the room temperature during the day saves energy Have your combi boiler s maintenance performed at least annually Provide your building with sufficient heat insulation Thermostatic valves should be used Each room should be adjusted according to comfort conditions For reception rooms this is 20 C living rooms 22 C kitchens 18 C and bedrooms 18 C Preven...

Страница 11: ...E1 73 Internal PCB error Perform reset if needed If problem repeats contact your service agent H9 01 Outside sensor fault Boiler continues operation but outside sensor is defective Contact your service agent HC 01 Domestic hot water temperature sensor fault Boiler continues operation but you must contact your service agent HJ 08 High system pressure Discharge water down to 0 8 bar You can bleed th...

Страница 12: ...who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference GAS BOILER SYSTEM COMMISSIONING CHECKLIST CONTROLS Programmable room thermostat Optimum start control Combination Boiler Fitted Fitted Fitted Automatic bypass to system Fitted Boiler interlock ALL SYSTEMS Yes Yes CENTRAL HEATING M...

Страница 13: ...It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed Service Provider SERVICE RECORD SERVICE 01 AND Where Possible AND Signature SERVICE 02 AND Where Possible AND Signature SERVICE 03 AND Where Possible AND Signature SERVICE 04 AND Where Possible AND Signature SERVICE 05 AND Where Possible AND Signature SERVICE 06 AND Where ...

Страница 14: ......

Страница 15: ......

Страница 16: ...STANBUL TÜRKİYE Tel 0216 453 27 00 Faks 0216 671 06 00 Çağrı Merkezi 444 999 0 Web www daikin com tr Gülsuyu Mahallesi Fevzi Çakmak Caddesi Burçak Sokak No 20 34848 Maltepe 3P469438 3M 2019 11 Copyright 2018 Daikin Verantwortung für Energie und Umwelt ...

Отзывы: