10
|
Configuration
Installer reference guide
46
CTXM-A, FTXM-A, ATXM-A
Daikin room air conditioner
4P518023-17P – 2023.06
10 Configuration
10.1 To set a different channel of the indoor unit infrared signal receiver
In case 2 indoor units are installed in 1 room, you can change the channel for the
infrared signal receiver on the indoor unit to avoid the wireless remote control
signal confusion.
Prerequisite:
Perform the following setting for only 1 of the units.
1
Remove the cover and the batteries from the remote control.
2
Cut the address jumper J4.
Address jumper J4
Address
Factory setting (uncut)
1
After cutting with nippers
2
a
a
Address jumper J4
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3
Turn the power supply on.
4
Press and
simultaneously.
5
Press
, select and press
.
Result:
The Daikin eye will start to blink.
b
a
a
Daikin eye
b
Indoor unit ON/OFF switch
6
Press the indoor unit ON/OFF switch while the Daikin eye is blinking.