SiUS121632EA
CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series Functions
Functions and Control
53
2.10 POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, the air conditioner can be operated
by increasing the indoor fan rotating speed and the compressor frequency.
Details
When
POWERFUL
button is pressed, the fan speed and target temperature are converted to the
following states for 20 minutes.
A
= 50 ~ 90 rpm (depending on the model)
Ex: POWERFUL operation in cooling
Note:
POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW or
OUTDOOR UNIT QUIET operation.
Operation mode
Fan speed
Target temperature
COOL H
tap
+
A
rpm
18°C (64.4°F)
DRY
Dry rotating speed +
A
rpm
Lowered by 2 ~ 2.5°C
(3.6 ~ 4.5°F)
HEAT
H tap +
A
rpm
30 ~ 31.5°C (86 ~ 88.7°F)
FAN
H tap +
A
rpm
—
AUTO
Same as cooling/heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R24589)
Target temp.
Fan
A
rpm
H tap
Set tap
20 minutes
Lower limit of cooling
temperature
Remote controller registers
20 minutes independently.
POWERFUL
ON
POWERFUL
OFF
Ending condition:
1. Lapse of 20 minutes
2. System operation OFF
3. POWERFUL operation OFF
18˚C (64.4˚F)