7
|
Maintenance and service
User reference guide
45
CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S)
Daikin room air conditioner
4P518786-10K – 2023.05
7.4 To open the front panel
Open the front panel using the user interface.
1
Stop operation.
2
Hold
on the user interface for at least 2 seconds.
Result:
The front panel will open.
Note:
Press and hold
again for at least 2 seconds to close the front panel.
3
Turn the power supply off.
4
Pull down both locks on the back of the front panel.
5
Open the front panel until the support fits into the fixing tab.
a
d
c
b
a
Lock (1 on each side)
b
Backside of the front panel
c
Fixing tab
d
Support
INFORMATION
If you CANNOT find the wireless remote control or you use another optional
controller. Pull the front panel carefully up by hand as shown in the following figure.
7.5 About the air filters
Operating the unit with dirty filters means that the filter:
▪
CANNOT deodorise the air,
▪
CANNOT clean the air,
▪
poor heating/cooling,
▪
causes odour.
List of treated articles used in Daikin products based on Regulation (EU) No
528/2012
Treated article ofa biocidal product
Air resin filter
Active substance
Silver phosphate glass
Content
<0,02 %
CAS Nr.
308069-39-8