Daikin CTKC25WVMG Скачать руководство пользователя страница 10

9

Read Before Operation

Basic Operation

Preparation Before Operation

 CAUTION

Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure.
Please observe the following precautions and use safely.

• 

If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and 

seek the attention of a medical professional.

• 

Keep batteries out of reach of children. In the event that batteries are swallowed, seek the immediate attention of a medical professional.

• 

Do not expose batteries to heat or fire. Do not disassemble or modify batteries. The insulation or gas release vent inside the battery may be 
damaged, resulting in battery leakage, rupturing, or heating.

• 

Do not damage or peel off labels on the batteries.

 

„

To insert the batteries

1.  Remove the back cover by sliding and then slightly lifting it.
2. 

Insert 2 dry batteries AAA.LR03 (alkaline).

3.  Replace the back cover.

 

„

To fix the remote controller holder 

 

to a wall

1. 

Choose a place from where the signals reach the unit.

2. 

Fix the holder to a wall, a pillar, or similar location with 

 

the screws supplied with the holder.

3.  Hang the remote controller on the remote controller holder.

 

„

To attach the filters (sold separately)

• 

If attaching the separately sold filters, attach them before turning 

 

the power on. 

 Page  21

 

„

Turn on the circuit breaker

• 

After the power is turned on, the flap of the indoor unit opens and 

 

closes once to set the reference position.

 

„

To check the function of the 

 

Wireless LAN connecting adapter

1.  Open the front panel. 

 Page  20

2.  Turn on the main power supply and check that the RUN lamp of  

the Wireless LAN connecting adapter lights.

3. 

Close the front panel. 

 Page  20

2

3

1

Position   and  

 correctly!

Remote controller

Remote 
controller holder

Screws

• 

When turning on the power, always 
attach the Wireless LAN connecting 

adapter case (upper).

NOTE

Notes on batteries

• 

To avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time.

• 

The standard replacement time is 1 year. Both batteries should be replaced at the same time. Be sure to replace them with new size AAA.LR03 

(alkaline) batteries.

• 

When battery power has run out, the LCD will begin blinking as an alert that the batteries need replacing. In some cases, when battery 
consumption is accelerated owing usage conditions, signal reception may decline before the LCD begins blinking.

•  The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.

Note on remote controller

• 

Do not drop the remote controller. Do not get it wet.

01_EN_3P529266-6D.indd   9

10/11/2564   8:31:52

Содержание CTKC25WVMG

Страница 1: ...MODEL CTKC25WVMG CTKC35WVMG DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL 00_CV_3P529266 6D indd 1 16 11 2564 8 44 02...

Страница 2: ...ion enables efficient operation by limiting the maximum power consumption It is useful when using the air conditioner and other electrical devices simultaneously on a shared electrical circuit Page 15...

Страница 3: ...ing the Airflow Rate 11 Adjusting the Airflow Direction 12 Useful Functions COMFORT AIRFLOW Operation 13 SUPER POWERFUL Operation 14 ECONO Operation 15 TIMER Operation ON OFF TIMER Operation 16 Mobile...

Страница 4: ...n and health Do not place objects including rods your fingers etc in the air inlet or outlet Product damage or personal injury may result due to contact with the air conditioner s high speed fan blade...

Страница 5: ...ge To avoid oxygen depletion ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner Before cleaning be sure to stop unit operation and tu...

Страница 6: ...or unit ON OFF switch Press this switch once to start operation Press once again to stop it For the operation mode setting refer to the following table Mode Temperature setting Airflow rate COOL 22 C...

Страница 7: ...rant pipes and inter unit wire Drain hose Air outlet Earth terminal inside Air inlet back and side Outdoor temperature sensor back Model name Air filter Wireless LAN connecting adapter Model name Wire...

Страница 8: ...C42 model 1 The RUN lamp LED can be disabled via the mobile application Make sure the controller is connected to the Wireless LAN adapter and RUN lamp is lit To turn off the RUN lamp via the mobile ap...

Страница 9: ...Page 14 OFF TIMER button NIGHT SET mode Page 17 ON TIMER button Page 16 Signal transmitter Receiver To use the remote controller aim the transmitter at the indoor unit If there is anything blocking th...

Страница 10: ...sold separately If attaching the separately sold filters attach them before turning the power on Page 21 Turn on the circuit breaker After the power is turned on the flap of the indoor unit opens and...

Страница 11: ...e OPERATION lamp goes off To change the temperature setting Press Press to raise the temperature and press to lower the temperature COOL operation DRY or FAN ONLY operation 18 32 C The temperature set...

Страница 12: ...t smaller airflow rates the cooling effect is also smaller Tips for saving energy Keeping the temperature setting at a moderate level helps save energy Recommended temperature setting For cooling 26 2...

Страница 13: ...de will begin to swing To set the flap at the desired position This function is effective while the flap is in auto swing mode Press when the flap reach the desired position disappears from the LCD To...

Страница 14: ...rection Goes up Airflow rate AUTO Not available in FAN ONLY mode To cancel COMFORT AIRFLOW operation Press again disappears from the LCD The flap will return to the memory position from before COMFORT...

Страница 15: ...from the LCD SUPER POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL operation To...

Страница 16: ...lable in FAN ONLY mode To cancel ECONO operation Press again disappears from the LCD NOTE Notes on ECONO operation This operation is performed with lower power and therefore may not provide a sufficie...

Страница 17: ...splayed on the LCD Each pressing of changes the time setting by 1 hour The time can be set between 1 and 12 hours The TIMER lamp lights orange Display To cancel ON TIMER operation Press disappears fro...

Страница 18: ...F TIMER operation A sample setting for combining the 2 timers is shown below and are displayed on the LCD Example When setting while the unit is operating Stops the unit 1 hour later and starts it 7 h...

Страница 19: ...a WPS button on the router Wireless LAN access point 1 Check that the RUN lamp is blinking 2 Push the WPS button on the router Wireless LAN access point Operation of the WPS differs according to the r...

Страница 20: ...Table 1 or to purchase the another type contact the dealer where you bought the air conditioner The method of cleaning and replacement of the filters may differ depending on the model Refer to the la...

Страница 21: ...lters with water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned wit...

Страница 22: ...when removing water from it Air quality filter enzyme blue with PM2 5 Blue White Dust collection filter PM 2 5 White Do not wash the filters as this will reduce their efficiency It is recommended to r...

Страница 23: ...batteries from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor...

Страница 24: ...a result of temperature changes Clicking sound during operation or idle time This sound is generated when the refrigerant control valves or the electrical parts operate Clopping sound This sound is he...

Страница 25: ...circuit breaker remove the obstruction Then restart operation with the remote controller If the OPERATION lamp is still blinking check the error code and consult your dealer Page 27 The air condition...

Страница 26: ...with new size AAA LR03 alkaline batteries Leaving exhausted batteries in the remote controller can result in injury due to battery leakage rupturing or heating or lead to equipment failure Even when...

Страница 27: ...bout how to operate the DAIKIN Mobile Controller application please refer to the operation manual at http www daikinthai com product dmobile Call your dealer immediately WARNING When an abnormality su...

Страница 28: ...URE SENSOR OUTDOOR UNIT E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTRO...

Страница 29: ...28 MEMO 01_EN_3P529266 6D indd 28 10 11 2564 8 31 57...

Страница 30: ...29 MEMO 01_EN_3P529266 6D indd 29 10 11 2564 8 31 57...

Страница 31: ...01_EN_3P529266 6D indd 30 10 11 2564 8 31 57...

Страница 32: ...3P529266 6D M21N068 2112 HT The two dimensional bar code is a manufacturing code Complies with IMDA Standards DA107930 00_CV_3P529266 6D indd 2 16 11 2564 8 44 03...