background image

BYCQ14 BYCQ140 BYCQ140E2GFW1B 

Installation manual

Self cleaning decoration panel

4P558847-1B 2019.02

6

107~1

12mm

6-2

 (6)

Panel

Lower side 

of panel

Indoor unit

Lower part of hook of 

the indoor unit

(The ceiling is 

omitted from the 

illustration for ease 

of explanation)

107~1

12mm

Seal

Indoor unit

Lower part of 

hook of the 

indoor unit

Ceiling

Mounting bracket

Lower side of panel

Panel

Cross sections (4 points)

Note

• Tighten the screws securely, or otherwise a defect as shown 

below may result.

• Readjust the height of the indoor unit if there is a space between 

the ceiling and panel with the screws tightened securely.

Air 

leakage

Air leakage 

from the 

ceiling side.

Generation 

of dirt

Dew condensation 

or dripping

Make sure that there is no space.

Height adjustments to the unit 

will be possible through the 

holes on the corners of the 

panels without removing the 

panel, provided that the 

adjustments does not affect the 

levelness or the drain piping of 

the indoor unit. Refer to the 

installation manual of the indoor 

unit to conduct the work.

6-3  Checking panel

(1) 

Remove sealing of panel.

1

2

1

2
3

4

Remove seal of panel

Insert the seal until the seal comes in contact with the 

claw

Claw 

Sealing (accessory (8))

(2) Draw the harness and lead wires (on the panel side).

Panel

Harness

Harnesses

Lead wires

(on the panel side)

Lead wire 

(on the panel side)

(3) 

Connect the connectors of the lead wires and move the glass 

tube to cover the connector part.

Lead wires 

(on the panel side)

Harnesses

Connector

Be sure to connect 

them securely.

Move the 

glass tube.

1

2

Glass tube

(4) 

Tighten and secure both ends of the glass tube with the 

clamps on the glass tube together with provided clamps 

(accessories (5)). Cut the redundant portions of the clamps 

from their roots after the both ends are secured.

Tighten the clamps

Cut the roots

Clamp

(accessory (5))

(5) 

Return the connected lead wires to the space between the 

indoor unit and panel. 

(Accommodate the lead wires in the shaded part shown in the 

illustration.)

Note

Accommodate the lead wires carefully so that the lead wires 

will not come in contact with the air filter.

Connected 

lead wires

Connected 

lead wires

Panel

EL. COMPO. BOX 

of the indoor unit

Содержание BYCQ140EGFB

Страница 1: ...Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel INSTALLATION MANUAL BYCQ140E2GW1 BYCQ140E2GFW1 BYCQ140E2GFW1B...

Страница 2: ...ag may be suffocated CAUTION Install the indoor and outdoor units power cord remote controller wiring and transmission wiring at least 1 m away from TV or radio sets This is for the prevention of TV a...

Страница 3: ...mer Did you deliver the operation manual to the customer Be sure to hand the customer the operation manual as well as the installation manual Did you hand the customer the connecting pipe and attachme...

Страница 4: ...top of the panel together with the accessories attached to the backside of the protective corrugated cardboard Protective corrugated cardboard top The accessories are on the backside Protective corrug...

Страница 5: ...an electric shock may be received CAUTION Conduct the following work after installing the indoor unit Install the indoor unit according to the installation manual provided with the indoor unit 5 1 Att...

Страница 6: ...l 1 Tentatively put the two temporary latching brackets of the suction port of the panel on the internal circumference side to the hooks of the indoor unit Note Remove your hands after confirming thro...

Страница 7: ...tallation manual of the indoor unit to conduct the work 6 3 Checking panel 1 Remove sealing of panel 1 2 1 2 3 4 1 Remove seal of panel 2 Insert the seal until the seal comes in contact with the claw...

Страница 8: ...own in the illustration 1 2 3 4 5 1 Clasp 2 Hooked fall prevention cord 3 Panel 4 Fall prevention cord 5 Dust box 2 Attach the dust box in the order opposite to the procedure in 4 3 Removal of dust bo...

Страница 9: ...e Clasp Fall prevention cord Clasp Bend the clasp inward Fall prevention cord 3 Connect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint...

Страница 10: ...rd 3 Connect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint Flexible hose junction on the panel side Fit the claws into the hooks in t...

Страница 11: ...selected for the filter auto cleaning of the self clean panel Operation mode Description 1 Scheduled timer operation Performs filter auto cleaning during the designated period selected from eight per...

Страница 12: ...ion after the power is turned on 10 3 Conduct the test operation of the panel two minutes after the power is turned on Confirm the cleaning operation of the filter with the remote controller Test oper...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...Copyright 2018 Daikin 4P558847 1B 2019 02...