12

B.  When the COOL/HEAT CHANGEOVER 

REMOTE CONTROL SWITCH is not provided 

Using the wireless remote controller, first follow 

the below procedure to assign the privilege to 
set cool/heat operations for other units to a 
indoor unit.

Outdoor unit

Indoor unit

Assign cool/heat selection 
privilege to an indoor unit

Outdoor unit

Indoor unit

Assign cool/heat selection 
privilege to an indoor unit

BS unit

1

Press and hold the OPERATION MODE 

SELECTOR button on the wireless 

remote controller for about 4 seconds.

The TIMER INDICATOR LAMP (Green) on the 
displays of all the indoor units connected to the 

same outdoor unit or BS unit will start flashing.

2

Point the wireless remote controller at the 

indoor unit to which cool/heat privilege is 

to be assigned and press the OPERATION 

MODE SELECTOR button again.

Setting is complete when the TIMER INDICATOR 
LAMP (Green) on the displays of all indoor units 

you are trying to set stop flashing.

TIMER INDICATOR LAMP 

To switch the operation using the wireless remote 
controller, point it at the indoor unit to which cool/heat 
selection privilege has been assigned. The operation 
of the indoor units without cool/heat selection privilege 
switches in accordance with the operation of the 
indoor unit assigned with cool/heat selection privilege.
To change the cool/heat selection privilege settings, 
perform steps   to   again.

*  If the wireless remote controller is operated while 

pointed at an indoor unit without cool/heat selection 
privilege, operation switching cannot be performed 
and an error tone (long beep) will sound.

01_EN_4P457494-6L.indd   12

13/03/2019   11:07:44

Содержание BRC7M675

Страница 1: ...ank you for purchasing this product Carefully read this manual to ensure proper operation and installation After reading the manual file it away for future reference Furthermore make certain that this...

Страница 2: ...1 13 2 6 1 3 7 8 12 10 9 11 4 5 18 14 19 17 20 15 16 Fig 1 1 Fig 1 3 Fig 1 2 Fig 2 27 28 COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH 24 23 22 26 25 21 00_CV_4P457494 6L indd 2 26 02 2019 20 45 22...

Страница 3: ...ymbol This chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Do not try to dismantle the system yourself the disma...

Страница 4: ...ial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they h...

Страница 5: ...e hazardous compounds Turn off the air conditioner and call your local dealer Turn on the air conditioner after the qualified service person makes sure to confirm that the leakage is repaired Do not p...

Страница 6: ...Never touch the internal parts of the remote controller Touching certain internal parts will cause electric shocks and damage to the remote controller Consult your local dealer about checking and adj...

Страница 7: ...PROGRAMMED TIME of the air conditioner start or stop 6 DISPLAY AIRFLOW BLADE Refer to page 9 10 7 DISPLAY FAN SPEED The display shows the set fan speed 8 DISPLAY INSPECTION When the INSPECTION BUTTON...

Страница 8: ...il to display information CAUTIONS Make sure to turn off the unit and disconnect the power supply breaker when taking care of the air conditioner Unless the power supply is disconnected it may cause e...

Страница 9: ...der centralized control it is necessary to switch the remote controller s setting In this case contact your local dealer 5 OPERATION RANGE If the temperature or the humidity is beyond the operation ra...

Страница 10: ...stops OPERATION The fan may keep on running for about 1 minute after the heating operation stops for removing the heat in the indoor unit NOTE Do not turn OFF power immediately after the unit stops Th...

Страница 11: ...ight receiving unit indicator lights Leave it as it stands and wait for a while The remote controller displays the fan speed that is set The air discharge direction becomes horizontal to prevent a dra...

Страница 12: ...pressed set temperature rises 1 C Each time this button is pressed set temperature lowers 1 C Temperature cannot be set in FAN OPERATION and PROGRAM DRY OPERATION modes In case of AUTOMATIC OPERATION...

Страница 13: ...on 4 Indoor unit Swing PROGRAM TIMER OPERATION Operate in the following order The timer is operated in the following two ways Programming the stop time OFF The air conditioner stops operating after th...

Страница 14: ...indoor units at once Refer to A on page 11 In systems where the COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH is not provided the privilege to activate cool heat operations for all indoor units can be as...

Страница 15: ...it to which cool heat privilege is to be assigned and press the OPERATION MODE SELECTOR button again Setting is complete when the TIMER INDICATOR LAMP Green on the displays of all indoor units you are...

Страница 16: ...l system one group of indoor units The air conditioner follows individual operation Cannot have two remote controller control system with only wireless remote controllers It will be a two remote contr...

Страница 17: ...air conditioner does not operate at all Check if the receiver is exposed of sunlight or strong light Keep receiver away from light Check if there are batteries in the remote controller Place the batt...

Страница 18: ...all steps from 3 to 6 1 short beep Perform 3 and 6 steps 1 long beep Normal state 3 Press OPERATION MODE SELECTOR button on the left hand of the malfunction code blinks 4 Press PROGRAMMING TIMER butto...

Страница 19: ...moderate injury It may also be used to alert against unsafe practices After the installation is completed test the air conditioner and check if the air conditioner operates properly Give the user ade...

Страница 20: ...reless remote controller for how to install 2 3 NOTE TO THE INSTALLER Have the customer actually operate the system while looking at the operation manual Instruct the customer how to operate the syste...

Страница 21: ...plied Refer to the following procedure and conduct initial set according to the combination of the indoor unit 1 The initial setting indication is displayed at the first time of the battery insertion...

Страница 22: ...and the wireless remote controller This includes an individual remote controller control using the group operation For the wiring for the group operation please refer to the installation manual attach...

Страница 23: ...nce is hard to discriminate with such circumstances there are two setting options provided to enable discriminating by a beeping sound according to the operation A Standard or b Multi System Refer to...

Страница 24: ...luded wire harness long 3 and wire harness short 4 wire harnesses to the connector on the transmission printed circuit board 2 CN1 X1A CN2 X2A Wire harness short 4 Wire harness long 3 Transmission pri...

Страница 25: ...2 in step 1 as follows Wire harness long 3 to connector X24A on the indoor unit printed circuit board Wire harness short 4 to connector CN1 X1A on the receiver assembly 1 Indoor unit printed circuit...

Страница 26: ...he front grille NOTE The hook positions are the same for both pre installed cover and control panel 2 Slide the cover to side while pushing the cover on A position from the back side and on B position...

Страница 27: ...mounted on the indoor unit the indoor unit setting may have to be changed Refer to the instruction manual optional hand book for each optional accessory 5 2 1 6 4 3 MODE NO SECOND CODE NO FIRST CODE N...

Страница 28: ...group control with a wireless remote controller initial settings for all the indoor units of the group are equal Refer to the installation manual attached to the indoor unit for group control 4 TEST...

Страница 29: ...26 NOTE 01_EN_4P457494 6L indd 26 13 03 2019 11 07 55...

Страница 30: ...27 NOTE 01_EN_4P457494 6L indd 27 13 03 2019 11 07 55...

Страница 31: ...01_EN_4P457494 6L indd 28 13 03 2019 11 07 55...

Страница 32: ...P L M18N125 1904 HT The two dimensional bar code is a manufacturing code The two dimensional bar code is a manufacturing code 00_CV_4P457494 6L indd 4 26 02 2019 20 45 23...

Отзывы: