Daikin BRC7E63W Скачать руководство пользователя страница 7

English

4

Placing the remote controller in the 
remote controller holder

Install the remote controller holder to a wall 
or a pillar with the attached screw. (Make 
sure it transmits)

How to put the dry batteries

(1)

Remove the back cover 
of the remote controller 
to the direction pointed 
by the arrow mark.

(2)

Put the batteries
Use two LR03<IEC> 
dry cell batteries. Put 
dry batteries correctly 
to fit their (+) and (–).

(3)

Close the cover

When to change batteries

Under normal use, batteries last about a 
year.  However, change them whenever the 
indoor unit doesn’t respond or responds 
slowly to commands, or if the display 
becomes dark.

Placing the remote
controller

Slide from above

Remote
controller
holder

Removing the
remote controller

Pull it upward

[CAUTIONS]

Replace all batteries at the same time, do 
not use new and old batteries intermixed.

In case the remote controller is not used 
for a long time take out all batteries in order 
to prevent liquid leak of the battery.

IN THE CASE OF CENTRALIZED 
CONTROL SYSTEM

If the indoor unit is under centralized control, it 
is necessary to switch the remote controller’s 
setting.
In this case, contact your DAIKIN dealer.

 Refer to figure 1 on page [1] 

Operating procedure varies with heat 
pump type and cooling only type. Contact 
your Daikin dealer to confirm your system 
type. 

To protect the unit, turn on the main power 
switch 6 hours before operation.

If the main power supply is turned off dur-
ing operation, operation will restart auto-
matically after the power turns back on 
again.

Operate in the following order.

AUTOMATIC OPERATION can be 
selected only by Heat recovery system.

For cooling only type, “COOLING”, and 
“FAN” and “DRY”operation are able to 
select.

4. OPERATION PROCEDURE

COOLING, HEATING, AUTOMATIC, 
FAN, AND PROGRAM DRY 
OPERATION

Содержание BRC7E63W

Страница 1: ...C7E66 Thank you for purchasing this Daikin air conditioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual file it away for future reference ...

Страница 2: ...ge of the system and maintenance The air conditioner corresponding to this controller comes under the term appliances accessible to the general public CONTENTS PRIOR TO USE 1 ILLUSTRATION 2 1 SAFETY CONSIDERATIONS 1 2 NAMES AND FUNCTIONS OF THE OPERATING SECTION 2 3 HANDLING FOR WIRELESS REMOTE CONTROLLER 3 4 OPERATION PROCEDURE 4 5 NOT MALFUNCTION OF THE AIR CONDITIONER 10 6 HOW TO DIAGNOSE TROUB...

Страница 3: ... 14 16 17 9 1 3 4 6 2 5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr hr TEST 2 24 25 COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH 19 21 20 22 23 18 1 1 3 2 ...

Страница 4: ... leakage electric shocks or fire 1 SAFETY CONSIDER ATIONS Ask your dealer to perform servicing or repairs whenever necessary Improper servicing or repairs could cause water leakage electric shocks or fire Do not stick your fingers or any other objects into the air inlet air outlet or air direction vanes during operation The high speed fan is dangerous and could cause injury Ask your dealer to remo...

Страница 5: ...TEMPERATURE SETTING BUTTON Use this button for SETTING TEMPER ATURE Operates with the front cover of the remote controller closed 11 PROGRAMMING TIMER BUTTON Use this button for programming START and or STOP time Operates with the front cover of the remote con troller opened 12 TIMER MODE START STOP BUTTON Refer to page 7 13 TIMER RESERVE CANCEL BUTTON Refer to page 8 14 AIR FLOW DIRECTION ADJUST ...

Страница 6: ...nd reinstalling the air fil ter press the filter sign reset button on the remote controller The air filter clean ing time indicator lamp on the receiver will go out Precautions in handling remote con troller Direct the transmitting part of the remote controller to the receiving part of the air conditioner If something blocks the transmitting and receiving path of the indoor unit and the remote con...

Страница 7: ... time do not use new and old batteries intermixed In case the remote controller is not used for a long time take out all batteries in order to prevent liquid leak of the battery IN THE CASE OF CENTRALIZED CONTROL SYSTEM If the indoor unit is under centralized control it is necessary to switch the remote controller s setting In this case contact your DAIKIN dealer Refer to figure 1 on page 1 Operat...

Страница 8: ...n OFF power immediately after the unit stops Then wait no less than 5 minutes Water is leaking or there is something else wrong with the unit FOR SYSTEMS WITH COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH Refer to figure 1 1 3 on page 1 1 MODE 2 ON OFF OPERATION MODE SELECTOR 1 Select OPERATION MODE with the COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH as follows COOLING OPERATION HEATING OPERATION FAN...

Страница 9: ...or For details contact the place of purchase For programming TEMPERATURE FAN SPEED and AIR FLOW DIRECTION follow the procedure shown below TEMPERATURE SETTING Press TEMPERATURE SETTING but ton and program the setting tempera ture Each time this button is pressed setting temperature rises 1 C Each time this button is pressed setting temperature lowers 1 C ADJUSTMENT DOWN UP DOWN UP In case of autom...

Страница 10: ...room temperature is higher than the set tem perature At defrost operation When operating continuously at horizontal air flow direction on parts in the air discharge outlet from dripping Operation mode includes automatic operation B LEFT AND RIGHT DIRECTION Adjusting air flow direction in the left and right direction Refer to Fig 1 NOTE Only make adjustments after you have stopped the air flow dire...

Страница 11: ...e system after 4 hours the system will stop after 3 hours and then 1 hour later the system will start After the timer is programmed the display shows the remaining time 2 DOWN UP DOWN UP 3 RESERVE 4 CANCEL MODE TIMER RESERVE CANCEL DOWN UP FAN TIME TEMP ON OFF C hr hr When the system is installed as shown below it is necessary to designate the master remote controller For Heat pump system When one...

Страница 12: ...as the master remote controller Then designation is completed This indoor unit is desig nated as the master remote controller and the display showing van ishes To change settings repeat steps and 1 MODE 2 MODE 1 2 EMERGENCY OPERATION When the remote controller does not work due to battery failure or the absence thereof use this switch which is located beside the discharge grille on the main unit W...

Страница 13: ...event overload of the system After 3 minutes the sys tem will turn on again automatically The system does not restart immedi ately when TEMPERATURE SETTING 5 NOT MALFUNCTION OF THE AIR CONDITIONER button is returned to the former posi tion after pushing the button It does not restart immediately because a safety device operates to prevent overload of the system After 3 minutes the system will turn...

Страница 14: ...nction code blinks Press PROGRAMMING TIMER BUTTON and change the malfunction code 2 DOWN UP 3 6 3 6 MODE 3 4 DOWN UP 5 MODE 6 DOWN UP Press until the indoor unit makes a long beep The malfunction code is fixed when the indoor unit makes a long beep Reset of the display Press OPERATION MODE SELECTOR BUTTON to get the display back to the normal stae II IN CASE BESIDES EMERGENCY STOP 1 The unit does ...

Страница 15: ...e of purchase in the fol lowing case WARNING When you detect a burning odor shut OFF power immediately and contact the place of purchase Using the equipment in anything but proper working condition can result in equipment damage electric shock and or fire 1 Nnmber Trouble The RUN lamp of the indoor unit is flashing and the unit does not work at all Remedial action Check the malfunction code A1 UF ...

Страница 16: ...3PA63363 21T EM00A046 0101 HT ...

Отзывы: