11
English
•
Only the master remote controller can
select HEATING, COOLING or AUTO-
MATIC (only Heat recovery system)
OPERATION.
When the indoor unit with master remote
controller is set to “COOL”, you can switch
over operation mode between “FAN”, “DRY”
and “COOL”.
When the indoor unit with master remote
controller is set to “HEAT”, you can switch
over operation mode between “FAN” and
“HEAT”.
When the indoor unit with master remote
controller is set to “FAN”, you cannot switch
operation mode.
When attempting settings than that con-
sented above, a “peep” is emitted as a warn-
ing.
Only with Heat recovery system, you can set
the indoor unit to AUTOMATIC. Attempting
to do so, a “peep” will be emitted as a warn-
ing.
How to designate the master remote
controller
Continuously press the OPER-
ATION MODE SELECTOR but-
ton for 4 seconds.
The displays showing “
” of all slave indoor
unit connected to the same outdoor unit or
BS unit flash.
Press the OPERATION MODE
SELECTOR button to the
indoor unit that you wish to designate
as the master remote controller. Then
designation is completed. This indoor
unit is designated as the master
remote controller and the display
showing “
” vanishes.
•
To change settings, repeat steps
and .
1
2
1
2
When the remote controller does not work
due to battery failure or the absence thereof,
use this switch which is located beside the
discharge grille on the main unit. When the
remote controller does not work, but the bat-
tery low indicator on it is not lit, contact your
dealer.
[START]
Press the EMERGENCY OPER-
ATION switch.
The machine runs in the previous mode.
The system operates with the previously set
air flow direction, and airflow rate.
[STOP]
Press the EMERGENCY OPER-
ATION switch again.
EMERGENCY OPERATION
1
1
•
2
2
01_EN_3P107422-29P.fm Page 11 Thursday, January 17, 2008 1:46 PM