12 Starting up the system

Installation and operation manual

9

BK+S
Wired remote controller
4P513691-1B – 2018.03

11.3.1

To close the controller

1

Click the front of the controller into the rear casing.

1

2

12

Starting up the system

The  controller  gets  its  power  from  the  indoor  unit.  It  will  start  up  as
soon as it is connected. For the controller to be operable, therefore
make sure the indoor unit is powered on.

Once  the  controller  is  powered,  it  will  automatically  start  up.  If  it  is
the first and only controller that is connected to the indoor unit, it will
automatically  get  designated  as  master  controller.  For  a  second
controller  to  get  designated  as  slave  controller,  manual  action  is
required.  For  instructions,  see 

"12.1  To  designate  a  controller  as

slave" on page 9

.

12.1

To designate a controller as slave

Prerequisite: 

A master controller is already connected to the indoor

unit.

1

Connect a second controller.

Result: 

It will start up automatically.

2

Wait for a U5 or U8 error to appear on the screen.

3

When  the  U5  or  U8  error  appears,  press 

  and  keep  it

pressed until "2" appears on the screen.

Result: 

The controller is now designated as slave.

13

Maintenance

13.1

Maintenance safety precautions

WARNING

Before  carrying  out  any  maintenance  or  repair  activities,
stop  system  operation  with  the  controller,  and  turn  off  the
power  supply  circuit  breaker. 

Possible  consequence:

electric shock or injury.

NOTICE

To clean the controller, do NOT use organic solvents, such
as paint thinner. 

Possible consequence: 

damage, electric

shock, or fire.

WARNING

Do 

not 

wash 

the 

remote 

controller. 

Possible

consequence: 

electric leakage, electric shock, or fire.

INFORMATION

When  the  dirt  on  the  surface  cannot  be  removed  easily
while  cleaning  the  controller,  soak  the  cloth  in  neutral
detergent diluted with water, squeeze the cloth tightly, and
clean the surface. Afterwards, wipe dry with a dry cloth.

13.2

To clean the controller

1

Wipe the screen and other surface parts of the controller with a
dry cloth.

13.3

Time to clean filter indication

When  the  indoor  unit  filter  is  dirty  and  needs  to  be  cleaned,  the

controller  will  indicate  this  by  displaying 

  in  the  top  left  corner  of

the  home  screen,  and  confronting  you  with  the  'Time  to  clean  filter'
screen  as  soon  as  you  try  to  enter  the  main  menu  from  the  home
screen.

13.3.1

To remove the Time to clean filter
indication

Prerequisite: 

On  trying  to  enter  the  main  menu  from  the  home

screen, you are confronted with the 'Time to clean filter' screen.

1

Clean the filter.

2

Press 

 to remove the 'Time to clean filter' indication.

Содержание BRC1H81K

Страница 1: ...Installation and operation manual Wired remote controller English Installation and operation manual Wired remote controller BRC1H81W BRC1H81K BRC1H81S...

Страница 2: ...ions Please read these general safety precautions carefully before installing air conditioning equipment and be sure to install the equipment correctly Failure to follow these instructions properly ma...

Страница 3: ...re how to install or operate the unit contact your dealer After finishing installation Conduct a trial operation to check for faults Explain the user how to operate the controller Ask the user to stor...

Страница 4: ...system is operating Bluetooth 1 Indicates that the controller is communicating with a mobile device for use with the Daikin Control Assistant app Centralised control Indicates that the system is contr...

Страница 5: ...tion mode Cooling In this mode cooling will be activated as required by the setpoint Heating In this mode heating will be activated as required by the setpoint Fan Only In this mode air circulates wit...

Страница 6: ...INFORMATION Ventilation settings can ONLY be made for heat reclaim ventilation units 6 5 1 Ventilation mode The heat reclaim ventilation unit can operate in various operation modes Icon Ventilation m...

Страница 7: ...ry to enter the main menu Maintenance screens Clean filter Replace filter Empty dust collector 8 Troubleshooting 8 1 Overview Troubleshooting When the system is in error and the controller presents yo...

Страница 8: ...e careful not to distort the rear casing by overtightening the mounting screws 11 2 Connecting the electrical wiring NOTICE The wiring for connection is NOT included NOTICE When wiring run the wiring...

Страница 9: ...Maintenance safety precautions WARNING Before carrying out any maintenance or repair activities stop system operation with the controller and turn off the power supply circuit breaker Possible consequ...

Страница 10: ......

Страница 11: ......

Страница 12: ...4P513691 1B 2018 03 Copyright 2017 Daikin APPROVED TA 2017 3281 OMAN TRA TRA TA R 5107 18 D100428 TRA REGISTERED No ER63033 18 DEALER No DA73526 18 005 18 TRC LPD 2018 60...

Отзывы: