Daikin BRC073A1 Скачать руководство пользователя страница 5

BRC073A1

Wired user interface

4P392190-1 – 2014.11

Installation and operation manual

4

7. Description of the items in the main menu

By default, the main menu can be accessed. To disable, refer to

"10. Enable/disable the menu/enter and cancel button" on page 9

.

1

AIRFLOW DIRECTION
Change the 

Airflow Direction

.

2

ENERGY SAVING OPTIONS

(1)

Energy Saving List

Enable or disable the Energy Saving Options.

Setpoint Range

The setpoint temperature range can be restricted for the

Cooling

Heating

 and 

Auto

 mode .

Setback Condition

Set the setback differential temperature beyond which the
unit returns to the OFF state.

Setpoint Auto Reset

Change the temperature setpoint to a preset temperature
setpoint after running for a set period of time, even if the
temperature setpoint has changed.

OFF Timer

The air conditioner is turned OFF automatically after the
selected time each time the air conditioner is activated.

3

SCHEDULE

(2)

Select when the operation modes start and/or stop for each
day of the week.

Up to 5 actions can be set for each day.

Both operation modes (

normal

 and 

setback

) can be selected.

Additionally the holiday settings and schedule nr. can be set.

4

MAINTENANCE INFORMATION
Display the service contact.

5

CONFIGURATION
Switch between the standard and detailed display. When the
detailed display is selected, the room temperature or outdoor
temperature can be displayed on the basic screen.

6

CURRENT SETTINGS
Display a list of the current settings of the available items.

7

CLOCK & CALENDAR
Configure the date and time. The time can be displayed in either
a 12 hour or 24 hour time format.

8

LANGUAGE
Choose the language depending on the language pack installed.

8. Airflow Direction

1

Display the 

Airflow Direction

 screen (refer to 

"17. Main menu

structure" on page 6

).

2

Select the desired airflow direction from 

Swing

 or 

Swing stop 

using

the  

buttons.

3

Push the   button to confirm the settings and return to the basic
screen.

9. Energy Saving Options

For more information refer to the detailed user reference guide.

10. Schedule

The schedule can be restricted in case a centralised control is
installed via the KRP928 interface adapter for Room Air Conditioner.

To enable/disable the schedule

1

Display the 

Enable/Disable 

screen (refer to 

"Appendix" on page 10

).

2

Press the 

 buttons to select 

Enable

 or 

Disable

.

3

Push   to display the confirmation screen.

4

Use  

to 

select 

Yes

 and push  .

To select the schedule number

1

Display the 

Select Schedule

 screen (refer to 

"Appendix" on page 10

).

2

Use 

 to change the setting to 

Schedule nr 1

Schedule nr 2

, or

Schedule nr 3

.

3

Push   to display the confirmation screen.

4

Use  

to 

select 

Yes

 and push  .

To use the holidays

The schedule timer will be disabled for the days that have been set
as a holiday.
1

Display the 

Holidays

 screen

 

(refer to 

"Appendix" on page 10

).

2

Use 

 to select the desired day. Push 

 to display 

 to set

the holiday.

3

Push   to display the confirmation screen.

4

Use  

to 

select 

Yes

 and push  .

NOTICE

Function availability depends on the indoor unit type.

(1)

Setback, Setpoint Range, Setback Condition and Setpoint Auto Reset 
should not be used when a centralised controller is installed via the 
KRP928 Interface Adapter for Room Air Conditioner.

(2)

The schedule will not be available when a centralised controller is installed 
via the KRP928 Interface Adapter for Room Air Conditioner.

NOTICE

Depending on the outdoor unit, the outdoor temperature is
not visible when the indoor unit is OFF.

Airflow Direction

Direction1

Swing

Setting

Return

Direction2

Swing stop 

INFORMATION

There are 2 possible directions:

The available airflow directions depend on the indoor
unit type.

Up/down

Left/right

Return

Setting

Enable/Disable 

Schedule 

Disable

Setting

Select Schedule

Schedule

Schedule nr 1

Return

Return

Setting

Schedule

Holidays
 Multiple Selection

Sun Mon Tue Wed Thu Fri Sat

Содержание BRC073A1

Страница 1: ...INSTALLATION AND OPERATION MANUAL BRC073A1 Wired user interface ...

Страница 2: ...autions carefully before installing the user interface Failure to follow these instructions properly may result in property damage or personal injury which may be serious depending on the circumstances 2 Features and functions The state of the art user interface offers full control over your installation 1 BASIC USER INTERFACE The basic user interface functions are ON OFF operation mode change ove...

Страница 3: ...w direction 3 MENU ENTER BUTTON Used to display the main menu or enter the selected item 4 UP DOWN BUTTON Used to raise lower the set temperature Used to highlight the next item on the upper lower side Used to change the selected item 5 RIGHT LEFT BUTTON Used to highlight the next item on the right left hand side The display contents are changed to the next previous screen 6 ON OFF BUTTON Press to...

Страница 4: ...ion will not function if the room temperature is too low 3 AUTOMATIC OPERATION In this mode the user interface will automatically switch between heating and cooling as required by the setpoint 4 COOLING OPERATION In this mode cooling will be activated as required by the setpoint or setback operation 5 HEATING OPERATION In this mode heating will be activated as required by the setpoint or setback o...

Страница 5: ...tion from Swing or Swing stop using the buttons 3 Push the button to confirm the settings and return to the basic screen 9 Energy Saving Options For more information refer to the detailed user reference guide 10 Schedule The schedule can be restricted in case a centralised control is installed via the KRP928 interface adapter for Room Air Conditioner To enable disable the schedule 1 Display the En...

Страница 6: ...just the contrast of the LCD 1 Display the Contrast adjustment screen refer to Appendix on page 10 2 Use to change the contrast 3 Push to confirm the setting 13 Current Settings 1 Display the Current Settings screen refer to Appendix on page 10 2 A list of the status of the current settings is displayed 3 Push to return to the Main Menu 14 Clock Calendar To set the date time 1 Display the Date Tim...

Страница 7: ...ing is applied takes priority In case of an operation mode conflict the other units will enter standby mode NOTICE COOL DRY and FAN operation can be used simultaneously If the conflict is not solved manually non priority units will automatically resume operation as soon as the priority unit stops operating It is NOT possible to enter the menu when the user interface indicates the MODE CONFLICT mes...

Страница 8: ...onal accessory KJB111A or KJB211A WARNING Carefully read these instructions before installation They will tell you how to install how to configure and how to use the unit properly Keep this manual in a handy place for future reference This is an option to be used in combination with Daikin units Refer to the installer reference guide and user reference guide of the units for installation and opera...

Страница 9: ...retainer and clamp Connect the user interface S1 to the adapter S19 and the adapter S6 to the indoor unit S21 7 Attach the upper case Align the upper case with the tabs of the lower case 6 points and insert the upper case begin with the bottom part Mounting with supplied wood screws Ø3 5 16 Mounting with supplied double face adhesive tape 3 1 2 1 3 1 2 PCB PCB S19 S21 S6 S1 1 1 BRCW901A 2 PCB 1 2 ...

Страница 10: ... Checking procedure of Error History Registration method of the Maintenance Contact Clock Calendar see also 14 Clock Calendar on page 5 Language see also 15 Language on page 6 Prohibit buttons Prohibition Function Prohibit Mode Software update with Updater Maintenance 1 General safety precautions Wipe the LCD display and the rest of the surface of the user interface with a dry cloth when they beco...

Страница 11: ...rrent Settings Clock Calendar Language Airflow Direction 9 10 11 12 13 14 15 Energy Saving Options Energy Saving List Setpoint Range Setback Condition Setpoint Auto Reset Off Timer Schedule Enable Disable Select Schedule Holidays Settings Maintenance Information Configuration Display Contrast Adjustment Display Display Mode Display Item Current Settings Language Clock Calendar Date Time 12H 24H Cl...

Страница 12: ...4P392190 1 2014 11 Copyright 2014 Daikin ...

Отзывы: