Indoor Unit Installation Drawings
WARNING
• Use only Daikin optional parts approved for this model.
Screws
(M4 × 16L)
Service lid
Caulk pipe
hole gap
with putty.
Wrap the insulation pipe
ZLWKWKH¿QLVKLQJWDSH
from bottom to top.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Bottom frame
Front grille
How to attach the indoor unit
Hook the claws of the bottom frame
to the mounting plate.
If the cla
ZVDUHGLI¿FXOWWRKRRN
remove the front grille.
How to remove the indoor unit
Push up the marked area (at the
lower part of the front grille) to
release the claws.
,ILWLVGLI¿FXOWWR
release, remove the front grille.
Opening service lid
Service lid is removable.
Opening
method
1) Remove the service lid screw.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
30mm or more from ceiling
Front panel
50mm or more from walls
(on both sides)
$LU¿OWHUV
Mounting
plate
Mounting plate
¿[LQJVFU
ew
¿HOGVXSSO\
: M4 × 25L)
Wireless remote controller
)L[LQJVFU
ew for remote
controller holder
¿HOGVXSSO\
: M3 × 20L)
Remote controller
holder
Before screwing the
remote controller holder
to the wall, make sure
that control signals are
properly received by
indoor unit.
Clip
Mark (rear side)
Mounting plate
IL[LQJVFUHZ
ILHOGVXSSO\0[/
Mounting plate
A
A
The mounting plate
should be installed on a
wall which must be strong
enough to support the
weight of the unit.
Class 15/20/25/35/42:
Class 50/60/71:
Titanium apatite photocatalytic
air-purifying filter (2)
B
Titanium apatite photocatalytic
air-purifying filter
Class 50/60/71:
Class 15/20/25/35/42:
Titanium apatite photocatalytic
air-purifying filter
Streamer
(Class 50/60/71
only)
3PEN393185-7L.book Page 4 Friday, February 26, 2016 7:49 AM