9

English

Indoor Unit Installation

6.

When connecting to an HA system

1) Remove the front grille. (5 screws)
2) Remove the metal plate electric parts box cover. (6 tabs)
3) Insert the connection cord to the HA connector “S21”.
4) Lay the connecting cord as shown in the figure below.
5) Restore the electric parts box cover and the front grill.

7.

Drain piping

1) Connect the drain hose, as described right.

2) Remove the air filters and pour some water into the drain pan to check the 

water flows smoothly.

3) When drain hose requires extension, obtain an extension hose commercially 

available. 
Be sure to thermally insulate the indoor section of the extension hose.

4) When connecting a rigid polyvinyl chloride pipe 

(nominal diameter 13mm) directly to the drain 
hose attached to the indoor unit as with 
embedded piping work, use any commercially 
available drain socket (nominal diameter 
13mm) as a joint.

Electric parts 
box cover

6 tabs

HA connector 
“S21”

HA harness

PCB

Electric parts box

The drain hose should

be inclined downward.

No trap is permitted.

Do not put the end

of the hose in water.

Indoor unit 
drain hose

φ

18

Extension drain hose

Heat insulation tube
(Field supply)

Drain hose supplied with 
the indoor unit

Commercially available drain 
socket 
(nominal diameter 13mm)

Commercially available rigid 
polyvinyl chloride pipe
(nominal diameter 13mm)

φ

18

01_EN_3P166464-1.fm  Page 9  Saturday, September 17, 2005  11:08 AM

Содержание ATXG25EV1B

Страница 1: ... Montaj kýlavuzlarý R410A Split serisi Installation manual R410A Split series Installationsanleitung Split Baureihe R410A Manuel d installation Série split R410A Montagehandleiding R410A Split systeem Manual de instalación Serie Split R410A Manuale d installazione Serie Multiambienti R410A Εγχειρßδιο εγκατÜστασηò διαιροýìενηò σειρÜò R410A Manual de Instalação Série split R410A Рóêоводство по монта...

Страница 2: ...in TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin T...

Страница 3: ...bles so that they do not put undue force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire If any refrigerant has leaked out during the installation work ventilate the room The refrigerant produces a toxic gas if exposed to flames After all installation is complete check to make sure that no refrig...

Страница 4: ...t is away from electronic ignition type fluorescent lamps inverter or rapid start type as they may shorten the remote control range 8 the unit is at least 1 metre away from any television or radio set unit may cause interference with the picture or sound 9 Install at the recommended height 1 8m 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find the site wh...

Страница 5: ...tlet vent panel 1 Insert the fixed axles located on either side of the outlet vent panel into the axle bearings in a hooking motion from above and slowly close the panel 3 How to remove and attach the front grill Removing the front grill 1 Remove the front panel and the outlet vent panel 2 Remove the 5 screws in the front grill 3 Disengage the 3 hooks in the front grill Look for the Attaching the ...

Страница 6: ...ts are installed in one room the two wireless remote controllers can be set for different addresses 6 PCB in the indoor unit 1 Remove the front panel 2 Remove the front grill 5 screws 3 Remove the electric parts box cover 6 tabs 4 Cut the address jumper JA on the indoor unit circuit board 7 Wireless remote controller 1 Cut the jumper J4 1 2 3 1 2 3 Tabs 2 Tabs 3 When removing from the side of the ...

Страница 7: ...oor unit 2 Attach the tabs on the bottom frame firmly onto the mounting plate 2 on either side Removing the indoor unit 1 Lift the marked parts on the bottom of the front grill pull the front grill towards yourself and disengage the tabs on the bottom of the frame 2 Lift up the indoor unit and remove it from the top of the mounting plate See 4 How to open the indoor unit service lid on p4 of the I...

Страница 8: ...t has a down slope toward the outside 2 Insert a wall pipe into the hole 3 Insert a wall cover into wall pipe 4 After completing refrigerant piping wiring and drain piping caulk pipe hole gap with putty 275 110 100 60 170 44 5 70 23 a b 182 150 48 35 44 5 840 Removed pipe port cover The removed pipe port cover can be kept in the mounting plate pocket Mounting plate A 260 190 Bolt size M10 Bolt siz...

Страница 9: ...Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape 2 Be sure to connect the drain hose to the drain port in place of a drain plug 1 Pull out the drain plug 2 Pull out the drain hose and reattach it on the left side 3 Reattach the drain plug on the right side 3 Pull in the refrigerant piping and lay it so that it matches the liquid and gas piping marked on the ...

Страница 10: ...ith wire retainer 5 Shape the wires so that the service lid fits securely then close service lid WARNING 1 Do not use tapped wires stand wires extensioncords or starbust connections as they may cause overtheating electrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may cause elect...

Страница 11: ... available Be sure to thermally insulate the indoor section of the extension hose 4 When connecting a rigid polyvinyl chloride pipe nominal diameter 13mm directly to the drain hose attached to the indoor unit as with embedded piping work use any commercially available drain socket nominal diameter 13mm as a joint Electric parts box cover 6 tabs HA connector S21 HA harness PCB Electric parts box Th...

Страница 12: ...vent damage to the flare nuts and escaping gas 2 To prevent gas leakage apply refrigeration machine oil on both inner and outer surfaces of the flare Use refrigeration oil for R410A 2 1 Caution on Piping Handling 1 Protect the open end of the pipe against dust and moisture 2 All pipe bends should be as gentle as possible Use a pipe bender for bending Bending radius should be 30 to 40mm or larger C...

Страница 13: ...and this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid side 25 35 class 50 class 25 35 50 class O D 9 5mm O D 12 7mm O D 6 4mm Thickness 0 8mm Thickness 0 8mm Gas pipe thermal insulation Liquid pipe thermal insulation 25 35 class 50 class 25 ...

Страница 14: ...me after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Test Items Symptom diagnostic display on RC Check Indoor and outdoor units are installed properly on solid bases Fall vibratio...

Страница 15: ... 0511 HT 3P166464 1 M05B043 ...

Отзывы: