Outdoor Fan / Fan Motor
Si001277
10
Removal Procedure
5. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the nut and
remove the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
2
Disconnect the
connector [S70].
[S70]: fan motor
3
Release the fan motor
lead wire from the
hooks.
(R18672)
D-cut
Nut
Outdoor fan
10 mm