Table of contents
Installation manual
3
RXQ-A_ARXQ-A
R32 split series
3P664524-2A – 2021.07
Table of contents
About this document..................................................................
2 Specific installer safety instructions
Outdoor unit...............................................................................
To remove the accessories from the outdoor unit.......
Preparing the installation site ....................................................
Installation site requirements of the outdoor unit ........
Mounting the outdoor unit..........................................................
To provide the installation structure ............................
To install the outdoor unit............................................
To provide drainage ....................................................
Preparing refrigerant piping .......................................................
Refrigerant piping requirements..................................
Refrigerant piping insulation .......................................
Refrigerant piping length and height difference ..........
Connecting the refrigerant piping ..............................................
To connect the refrigerant piping to the outdoor unit ..
Checking the refrigerant piping .................................................
To check for leaks.......................................................
To perform vacuum drying ..........................................
About the refrigerant..................................................................
To determine the additional refrigerant amount ........................
To determine the complete recharge amount ...........................
To charge additional refrigerant ................................................
To fix the fluorinated greenhouse gases label...........................
Specifications of standard wiring components ..........................
To connect the electrical wiring to the outdoor unit ...................
8 Finishing the outdoor unit installation
To finish the outdoor unit installation.........................................
Checklist before commissioning ................................................
Checklist during commissioning ................................................
To perform a test run .................................................................
Wiring diagram ..........................................................................
Unified wiring diagram legend..................................... 12
1
About the documentation
1.1
About this document
INFORMATION
Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.
Target audience
Authorised installers
WARNING
Make sure installation, servicing, maintenance, repair and
applied materials follow the instructions from Daikin and, in
addition, comply with applicable legislation and are
performed by qualified persons only. In Europe and areas
where IEC standards apply, EN/IEC 60335-2-40 is the
applicable standard.
INFORMATION
This document only describes installation instructions
specific to the outdoor unit. For installation of the indoor
unit (mounting the indoor unit, connecting the refrigerant
piping to the indoor unit, connecting the electrical wiring to
the indoor unit …), see the installation manual of the indoor
unit.
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪
General safety precautions:
▪ Safety instructions that you MUST read before installing
▪ Format: Paper (in the box of the outdoor unit)
▪
Outdoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
▪
Installer reference guide:
▪ Preparation of the installation, reference data,…
▪ Format: Digital files on
http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Technical engineering data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
2
Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Unit installation (see
6])
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
"4.1 Preparing the installation site"
CAUTION
▪ Check if the installation location can support the unit's
weight. Poor installation is hazardous. It can also cause
vibrations or unusual operating noise.
▪ Provide sufficient service space.
▪ Do NOT install the unit so that it is in contact with a
ceiling or a wall, as this may cause vibrations.
Содержание ARXQ25AMV1B
Страница 14: ......
Страница 15: ......
Страница 16: ...3P664524 2A 2021 07 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...