SiBE04-809
Indoor Unit
Removal Procedure
135
1.4
Removal of Lamp Cover
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the front grille.
1. Remove the lamp cover.
1
Release the 2 hooks
carefully.
2
Release the 3 hooks
while rotating the lamp
cover and remove.
ON/OFF button
Hooks
Lamp cover
(R5037)
Film
(R5038)