Outdoor Unit
SiBE04-809
168
Removal Procedure
4
Disconnect the fan
motor connector [S70].
5
The illustration shows
arrangement of the fan
motor lead wire.
6
Loosen the fixing hooks
and release the lead
wire.
Put the lead wire through the
back of the motor when
reassembling. (so as not to
be entangled with the
propeller fan)
7
Loosen the 4 screws to
remove the
fan motor
.
DC fan motor
Step
Procedure
Points
S70
(R7199)
Fan motor
lead wire
(R7200)
(R7201)
(R3249)
Lead wire
Propeller fan
Fan motor
(R7202)