Removal of Compressor ASSY
Si011196
14
Removal Procedure
7. Removal of Compressor ASSY
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
2
Disconnect the
compressor lead wires.
Be careful so as not to burn
the compressor terminals or
the name plate.
S: yellow
C: blue
R: red
3
Remove the gasket.
Terminal cover
(R5455)
(R5455)
Terminal
cover
fixture
(R5456)
Yellow (S)
Blue (C)
Red (R)
(R5457)
(R12819)
S
R
C
Gasket
(R5458)