2
|
Troubleshooting
Service manual
20
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
Possible cause:
Faulty water temperature setting.
3
Perform a check of the 3-way valve. See
86].
Possible cause:
Faulty 3‑way valve.
4
Perform a check of the operation of the Aquastat. See
307].
Possible cause:
Faulty Aquastat.
INFORMATION
If all procedures listed above have been performed and the problem is still present,
contact the helpdesk.
2.3.14 A1-00 – Zero cross detection problem
Trigger
Effect
Reset
Power supply
abnormality. The sinus of
the power supply crosses
the 0‑axis too often in
±10 seconds.
Unit will stop operating.
Manual reset via user
interface.
Power reset.
To solve the error code
INFORMATION
It is recommended to perform the checks in the listed order.
1
Perform a check of the main PCB. See
Possible cause:
Faulty main PCB.
2
Perform a check of the noise filter PCB. See
Possible cause:
Faulty noise filter PCB.
3
Check if the power supply is conform with the regulations. See
284].
Possible cause:
▪
Faulty or disturbance of the power supply (imbalance >4%),
▪
Power drop,
▪
Short circuit.
INFORMATION
If all procedures listed above have been performed and the problem is still present,
contact the helpdesk.
2.3.15 A5-00 – Outdoor unit: High pressure peak cut / freeze protection problem
Trigger
Effect
Reset
Pressure is too high in
heating / domestic hot
water, too low in cooling.
Unit will stop operating.
Manual reset via user
interface.
Содержание ALTHERMA