Daikin Altherma FWXV10AATV3 Скачать руководство пользователя страница 2

2

DAIKIN EUROPE N.V.

We want to thank you for choosing one of our products.

We are confident that you will be happy with your selection because it represents the state of the art 
in the technology of home climate control.

By following the suggestions contained in this manual, the product you have purchased will operate 
without problems giving you optimum room temperatures with minimum energy costs.

Conformity

This unit complies with European directives:
•   Low voltage directive 2014/35/UE

•   Electro-magnetic compatibility 2014/30/UE;.

The following symbols provide  the necessary information 
for correct, safe use of the machine in a rapid, unmistakable 

way

Symbols

U

 User

Refers to pages containing instructions or information 
for the user.

I

 Installer

Refers to pages containing instructions or information 
for the installer

S

 Service

Refers to pages containing instructions or information 
for the installer TECHNICAL CUSTOMER SERVICE.

Editorial pictograms

Safety pictograms

  Generic danger

-  Signals that the operation described could cause 

physical injury if not performed according to the safety 
rules.

  Danger of high voltage

-  Signals that the operation described could cause 

electrocution if not performed according to the safety 
rules.

  Danger due to heat

Signals that the operation described could cause burns 
if not performed according to the safety rules.

  Do Not

-  Refers to actions that absolutely must not be 

performed.

Содержание Altherma FWXV10AATV3

Страница 1: ...FWXV10AATV3 R FWXV15AATV3 R FWXV20AATV3 R FWXM10AATV3 R FWXM15AATV3 R FWXM20AATV3 R INSTALLATION MANUAL Daikin Altherma Heat pump convector...

Страница 2: ...of the machine in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I Installer Refers to pages containing instructions or information for the...

Страница 3: ...nal components 8 2 5 Removing the side panels 9 2 6 Vertical installation 9 2 7 Horizontal or ceiling installation 10 2 8 Hydraulic connections 10 2 9 Condensation discharge 11 2 10 Filling the system...

Страница 4: ...e direct air flow Do not leave the room closed for long periods Periodically open the windows to ensure a correct change of air This instruction leaflet is an integral part of the appliance and conseq...

Страница 5: ...ng materials which could become a source of danger It is forbidden to climb onto the appliance or rest any object on it The external parts of the appliance can reach temperatures of more than 70 C Pro...

Страница 6: ...U M FWXV10AATV3 R FWXV15AATV3 R FWXV20AATV3 R A mm 999 1199 1399 U M FWXM10AATV3 R FWXM15AATV3 R FWXM20AATV3 R A mm 578 778 978 A FWXV FWXM 135 mm 601 mm A GENERAL Dimensions Overall dimensions 2 pipe...

Страница 7: ...he discharge of the condensation outside in case of ceiling installation FWXM series the airflow is not directed towards persons The following descriptions of the various mounting phases and the relat...

Страница 8: ...chine follow the procedures below Remove the upper grill loosen the fixing screws of the upper grill remove the grill Remove the front grill extract the grill until it is completely out of the seat ti...

Страница 9: ...he brackets can be adjusted with a spirit level Install the unit at level with a possible 1 2 tolerance towards the drainage pipe to facilitate the flow of water Fully tighten the four screws to block...

Страница 10: ...kage Wall plugs Brackets Screws Drainage pipe Hydraulic connections NB the nominal diameter unless otherwise indicated always refers to the internal diameter To avoid the formation of surface condensa...

Страница 11: ...tainer it must be open to the atmosphere and the tube must not be immersed in water to avoid problems of adhesiveness and counter pressure that would interfere with the normal outflow If there is a he...

Страница 12: ...he same collection bowl insulate the bowl condensation discharge pipe along all of its length Breather Filling the system Evacuating air while filling the system When starting up the system make sure...

Страница 13: ...tegory III Maintenance Cleaning the outside Routine maintenance is indispensable to keep the heat pump convector in perfect working condition safe and reliable over the years This can be done every si...

Страница 14: ...the seat tilt the grill and slide it outwards then remove the filter by pulling it outwards Extraction of filter cells After a period of continuous operation and in consideration of the concentration...

Страница 15: ...fan with the mobile panel missing or out of position After finishing the cleaning of the filter check that the panel is mounted correctly Cleaning filtering seats For the versions with a grill with fl...

Страница 16: ...t activate even if there is hot or cold water in the hydraulic circuit The hydraulic valve remains closed Dismount the valve body and check if the water circulation is restored Check the working effic...

Страница 17: ...drainage pipe The condensation discharge does not need an inclination for correct drainage The connection pipes and the valve unit are not insulated well Check the insulation of the pipes The applian...

Страница 18: ...18 S I U...

Страница 19: ...19 S I U EN...

Страница 20: ...Copyright 2019 Daikin cod N420249A 03...

Отзывы: