17
S
I
U
INSTALLATION
Effect
Cause
Remedy
The appliance leaks water only during
the cooling function.
The condensation bowl is blocked.
Slowly pour a bottle of water in the
low part of the battery to check the
drainage; if necessary, clean the bowl
and/or increase the inclination of the
drainage pipe.
The condensation discharge does not
need an inclination for correct drainage.
The connection pipes and the valve unit
are not insulated well.
Check the insulation of the pipes.
The appliance makes a strange noise.
The fan touches the structure.
Check the clogging of filters and clean
them if necessary
The fan is unbalanced.
The unbalancing causes excessive
vibrations of the machine; replace the
fan.
Check the clogging of filters and clean
them if necessary
Clean the filters