14 Technical data
Installer reference guide
86
ERLQ004~008CA + 08S18CB
Daikin Altherma – Low temperature split
4P401676-1 – 2015.02
14.7
Technical specifications
14.7.1
Technical specifications: Outdoor unit
Nominal capacity and nominal input
Outdoor units
ERLQ004CAV3
ERLQ006CAV3
ERLQ008CAV3
Indoor units
EHVZ04
EHVZ08
Condition 1
(a)
Heating capacity
Minimum
1.80 kW
Nominal
4.40 kW
6.00 kW
7.40 kW
Maximum
5.12 kW
8.35 kW
10.02 kW
Cooling capacity
Minimum
—
Nominal
—
Maximum
—
Heating PI
Nominal
0.87 kW
1.27 kW
1.66 kW
Cooling PI
Nominal
—
COP
Nominal
5.04
4.74
4.45
EER
Nominal
—
Condition 2
(b)
Heating capacity
Minimum
1.80 kW
Nominal
4.03 kW
5.67 kW
6.89 kW
Maximum
4.90 kW
7.95 kW
9.53 kW
Cooling capacity
Minimum
—
Nominal
—
Maximum
—
Heating PI
Nominal
1.13 kW
1.59 kW
2.01 kW
Cooling PI
Nominal
—
COP
Nominal
3.58
3.56
3.42
EER
Nominal
—
(a)
In heating: Ambient temperature DB/WB 7°C/6°C – leaving water condenser 35°C (DT=5°C). In cooling: Ambient temperature 35°C – leaving
water evaporator 18°C (DT=5°C)
(b)
In heating: Ambient temperature DB/WB 7°C/6°C – leaving water condenser 45°C (DT=5°C). In cooling: Ambient temperature 35°C – leaving
water evaporator 7°C (DT=5°C)
Technical specifications
Outdoor units
ERLQ004CAV3
ERLQ006CAV3
ERLQ008CAV3
Casing
Colour
Ivory white
Material
Polyester painted galvanised steel
Dimensions
Packing (H×W×D)
797×990×390 mm
Unit (H×W×D)
735×832×307 mm
Weight
Machine weight
54 kg
56 kg
Gross weight
57 kg
59 kg
Packing
Material
EPS, carton
Weight
3 kg
Heat exchanger
Specifications
Length
845 mm
Nr. of rows
2
Fin pitch
1.8 mm
Nr. of passes
—
Face area
—
Nr. of stages
32
Tube type
Ø8 Hi-Xa