4 Operation
User reference guide
12
EHBH/X04+08DA + EHVH/X04+08S18+23DA
Daikin Altherma – Low temperature split
4P495250-1 – 2017.12
Electricity price=12.49+5
Electricity price=17.49
Price
Value in breadcrumb
Gas: 4.08 /kWh
[7.6]=8.6
Electricity: 12.49 /kWh
[7.5.1]=17
4.7.3
Using and programming schedules
About schedules
Depending on your system layout and installer configuration,
schedules for multiple controls may be available.
You can:
▪ Select which schedules you currently want to use.
▪ Program your own schedules if the predefined schedules are not
satisfactory. The actions you can program are control specific.
Possible scheduling screens
Name and location
Usage
[1.2] Room > Heating
schedule
Program the desired room temperature
in heating mode.
[1.3] Room > Cooling
schedule
Program the desired room temperature
in cooling mode.
[2.2] Main zone > Heating
schedule
Program the desired leaving water
temperature for the main zone in
heating mode.
[2.3] Main zone > Cooling
schedule
Program the desired leaving water
temperature for the main zone in
cooling mode.
[3.2] Additional zone >
Heating schedule
Program the desired leaving water
temperature for the additional zone in
heating mode.
[3.3] Additional zone >
Cooling schedule
Program the desired leaving water
temperature for the additional zone in
cooling mode.
[4.2] Space heating/
cooling > Operation mode
schedule
"4.4.2 Setting the space operation
[5.5] Tank > Schedule
Program the domestic hot water tank
temperature for your normal domestic
hot water needs:
▪ Comfort
▪ Eco
▪ Stop
[7.4.2] User settings >
Quiet > Schedule
Program when the unit has to use which
quiet mode level:
▪ Off
▪ Quiet
▪ More quiet
▪ Most quiet
[7.5.4] User settings >
Electricity price >
Schedule
Program when a certain electricity tariff
is valid.
Example of programming a schedule
See
"4.7.4 Schedule screen: Example" on page 12
.
4.7.4
Schedule screen: Example
This example shows how to set a room temperature schedule in
heating mode for the main zone.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule
Example:
You want to program the following schedule:
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Prerequisite:
The room temperature schedule is only available if
room thermostat control is active. If leaving water temperature
control is active, you can program the main zone schedule instead.
1
Go to the schedule.
2
Clear the contents of the schedule (optional).
3
Program the schedule for Monday.
4
Copy the schedule to the other weekdays.
5
Program the schedule for Saturday and copy it to Sunday.
6
Give the schedule a name.
To go to the schedule:
1
Go to [1.1]: Room > Schedule.
2
Set scheduling to Yes.
3
Go to [1.2]: Room > Heating schedule.
To clear the contents of the schedule:
1
Select the name of the current schedule.
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
2
Select Delete.
Edit
Delete
3
Select OK to confirm.
To program the schedule for Monday:
1
Select Monday.
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
2
Select Edit.
Delete
Copy
Edit