14 Technical data
Installer reference guide
94
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
14.4.2
Components: Indoor unit
a
b
c
a
b c
d
10+12 HP
a
Switch box
Contains the main electronic and electrical parts of the
indoor unit.
b
User interface (optional)
c
Manometer
Allows readout of the water pressure in the water circuit.
d
Air purge valve
Remaining air in the water circuit will be automatically
removed via the air purge valve.
e
Expansion vessel (10 l)
f
Flow sensor
Gives feedback to the interface about the actual flow. Based
on this information (and other), the interface adjusts the
pump speed.
g
Heat exchanger
h
Water pump
Circulates the water in the water circuit.
i
Water filter
Removes dirt from the water to prevent damage to the pump
or blockage of the heat exchanger.
j
Pressure relief valve
Prevents excessive water pressure in the water circuit by
opening at 3 bar.
k
Refrigerant gas connection R410A
l
Refrigerant liquid connection R410A
m
Water inlet connection
n
Drain and fill valves
o
Shut-off valves (accessory)
Allows isolation of the indoor unit water circuit side from the
residential water circuit side.
p
Water outlet connection
q
Thermistors
Determines the water and refrigerant temperature at various
points in the circuit.
r
Backup heater thermal fuse
The fuse is blown when the temperature becomes higher
than the backup heater thermal protector temperature.
s
Backup heater thermal protector
The protector activates when the temperature of the backup
heater becomes too high.
t
Backup heater
Provides additional heating in case of cold outdoor
temperatures. Also serves as backup in case of
malfunctioning of the outdoor unit.
u
Air valve
14.4.3
Components: Switch box (indoor unit)
X4M
F1B F2B
TR1
X5M
X2M
X6Y
X6YA
X6YB
X1M
FU1
A1P
Q1L
K1M
K1M
X6M
X6M
X7M
X7M
K2M
K2M
K5M
K5M
K3M
K3M
d
d
a
b
c
c
d
e
p
g
h
i
k
j
q
f
s
r
o
n
m
l
a
Backup heater thermal protector Q1L
b
Transformer TR1
c
Terminals for backup heater X6M/X7M (*9W models only)
d
Backup heater contactors K1M, K2M and K5M
e
Booster heater contactor K3M (only for installations with a domestic
hot water tank)
f
Connectors X6YA/X6YB/X6Y
g
Backup heater circuit breaker F1B
h
Booster heater circuit breaker F2B. (Only for installations with
domestic hot water tank)
i
Terminal block X2M (high voltage)
j
Terminal block X4M. (Only for installations with domestic hot water
tank)
k
Terminal block X1M (to outdoor unit)
l
Cable tie mountings
m
Digital I/O PCB A4P (only for installations with solar kit or digital I/O
PCB kit)
n
Demand PCB for power limitation
o
Terminal block X5M (low voltage)
p
Socket X13A, receives the K3M connector. (Only for installations with
domestic hot water tank)
q
Main PCB A1P
r
Socket X9A, receives the thermistor connector. (Only for installations
with domestic hot water tank)
s
PCB fuse FU1