
• Domestic hot water tank • EKHWE
• Altherma
TM
• Domestic hot water tank
248
3
Capacity tables
3 - 1
Cooling capacity tables
4
3
4TW57859-1
The ALTHERMA by Daikin heat pump in combination with the optional domestic hot water tank provide hot water for household usage.
The below mentioned date allow a proper selection of the domestic hot water tank size for maximum comfort and efficiency.
(1) Domestic hot water volume:
The volume of hot water available for domestic usage depends on the physical volume of the tank, on the domestic water setpoint temperature and on the temperature spreading
in the tank.
Therefore we define the equivalent hot water volume (EHWV).
Definition:
EHWV = the volume of hot water available for domestic usage at a temperature of 40°C.
40°C is considered a comfortable domestic hot water temperature.
Tank
Setpoint temp.
(°C)
EHWV (l)
Usage pattern
Modest
Medium
High
150L
55
125
-
-
-
65
165
+
-
-
75
185
++
+
-
200L
55
200
+
-
-
65
230
++
+
-
75
260
++
++
-
300L
55
320
++
++
-
65
400
++
++
+
75
435
++
++
++
Grade
++
Excessive availability of domestic hot water.
+
Sufficient availability of domestic hot water.
-
Temporary shortage of domestic hot water can occur.
Usage pattern
Modest
Daily demand up tp 220 l -> typcial 2-persons usage pattern.
Medium
Daily demand up to 325 l -> typical 3 to 4 persons usage pattern.
High
Daily demand up to 550 l -> 4 to 6 persons usage pattern.
(2) Heat-up time:
Definition:
Heat-up time The time required to reheat the domestic hot water tank to 55°C after tapping a certain volume of hot water at 40°C.
note: changing the field settings (see installation manual) can influence the heat-up time.
Tank
Setpoint temp.
(°C)
Heat-up time for 150 L (bath)
<min>
Heat-up time for 50 L (shower)
<min>
150L
55
60
45
200L
55
60
40
300L
55
50
30
Conditions for testing: Ta = 7°CDB / 6°CWB, Troom = 20°C, Tstart = 10°C, outdoor unit type: ERHQ011
(3) Efficiency of domestic hot water production:
In the ALTHERMA by Daikin system both the heat pump and the electric booster heater supply the energy to produce domestic hot water.
The higher the portion of energy supplied by the heat pump, the more energy efficient the system is.
Lowering the setpoint temperature increases the portion of energy supplied by the heat pump and thus the efficiency of the system.
Definition:
Heat pump portion Percentage of energy supplied by the heat pump in the total energy need for domestic hot water.
Heat
pump
portion
Setpoint temp. (°C)
Conditions:
Real life condition
Simulation of a daily usage based upon
′
medium
′
usage pattern.
Outdoor temperature
7°CDB / 6°CWB
Room temperature
20°CDB
Outdoor unit type
ERHQ011
Tank type
200l
Field settings
Default field settings (see installation manual).
(4) Heat losses of domestic hot water tank:
Tank
EKHWE
Heat losses*
[kWh/24h]
150L
1.7
200L
1.9
300L
2,5
* Heat losses at
_
45°C between hot water in tank and surrounding air.
Содержание Altherma EDLQ011-016AA6V3
Страница 1: ...technical data EEDEN09 720 Altherma TM ...
Страница 3: ...technical data EEDEN09 720 Altherma TM ...
Страница 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Страница 6: ......
Страница 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Страница 8: ......
Страница 20: ......
Страница 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Страница 36: ......
Страница 52: ......
Страница 68: ......
Страница 84: ......
Страница 176: ......
Страница 196: ......
Страница 216: ......
Страница 236: ......
Страница 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Страница 238: ......
Страница 260: ... Room thermostat EKRTW AlthermaTM Room thermostat 260 1 Features 4 1 R o o m t h e r m o s A l t h e r m a E K R T W ...
Страница 264: ......
Страница 266: ... Room thermostat EKRTR AlthermaTM Room thermostat 266 1 Features 4 1 R o o m t h e r m o s A l t h e r m a E K R T R ...
Страница 270: ......