5 Setting the energy prices
User reference guide
21
07CAV3
Daikin Altherma low temperature monobloc
4P405545-1C – 2018.06
4.10
Installer settings: Tables to be
filled in by installer
4.10.1
Quick wizard
Setting
Default
Fill in…
Space heating/cooling settings [A.2.1]
Unit control method
2 (RT)
User interface location
1 (Room)
Number of LWT zones
1 (1 LWT zone)
Pump operation mode
2 (Request)
Glycol present
0 (No)
Outdoor unit [A.2.2]
DHW pump
0 (No)
External sensor (outdoor)
0 (No)
Control box [A.2.2.E]
Backup heater steps
0
BUH type
1 (1P,(1/1+2))
Preferential kWh rate
0 (No)
DHW operation
0 (No)
Contact type main
1 (Thermo)
Contact type add.
1 (Thermo)
Option box [A.2.2.F]
Ext. backup heat src
0 (No)
Alarm output
0 (NO)
External kWh meter 1
0 (No)
External kWh meter 2
0 (No)
External sensor (indoor)
0 (No)
PCC by digital inputs
0 (No)
Capacities [A.2.3]
Booster heater
3 kW
BUH: step 1
Depends on
model
BUH: step 2
Depends on
model
4.10.2
Space heating/cooling control
Setting
Default
Fill in…
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
1 (WD)
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
1 (WD)
Leaving water temperature: Delta T source [A.3.1.3]
Heating
5°C
Cooling
5°C
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
1 (Yes)
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
0 (Quick)
4.10.3
Domestic hot water control [A.4]
Setting
Default
Fill in…
Type
1 (R+S)
Maximum setpoint
60°C
INFORMATION
There is a risk of space heating (cooling) capacity
shortage/comfort problem (in case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruption will happen) when selecting [6‑0D]=0 ([A.4.1]
Domestic hot water Type=Reheat only) in case of a
domestic hot water tank without an internal booster heater.
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating/cooling and capacity shortage comfort
problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruptions will happen.
4.10.4
Contact/helpdesk number [6.3.2]
Setting
Default
Fill in…
Contact/helpdesk number
—
5
Setting the energy prices
If your system's savings mode is set to Economical, it allows you to
set:
▪ a fixed fuel price
▪ 3 electricity price levels
▪ a weekly schedule timer for electricity prices.
The savings mode is set by the installer and can be either ecological
or economical. In ecological mode, the primary energy use is
minimised; in economical mode, the running costs. Discuss with the
installer which savings mode is preferred. Refer to the installation
manual for more information.
Example: How to set the energy prices on the user interface?
Price
Value in breadcrumb
Fuel: 5.3 euro cent/kWh
[7.4.6]=5.3
Fuel: 4.8 pence/kWh
[7.4.6]=4.8
Electricity: 12 euro cent/kWh
[7.4.5.1]=12
Electricity: 12.49 pence/kWh
[7.4.5.1]=12
5.1
To set the fuel price
1
Go to [7.4.6]:
> User settings > Preset values > Fuel price.
2
Use
and
to set the correct price.
3
Press
to confirm.
INFORMATION
▪ Price value ranging from 0.00~290 valuta/MBtu (with 2
significant values).
▪ Price value ranging from 0.00~990 valuta/kWh (with 2
significant values).
5.2
To set the electricity price
1
Go to [7.4.5]:
> User settings > Preset values > Elec price.
2
Use
and
to set the correct prices for High, Medium and
Low, according to your electricity tariff.
3
Press
to confirm.
INFORMATION
Price value ranging from 0.00~990 valuta/kWh (with 2
significant values).