Daikin Altherma EBLQ016CAV3 Скачать руководство пользователя страница 15

4 Operation

User reference guide

15

EBLQ+EDLQ011~W1 + EK(2)CB
EKMB9W1
Daikin Altherma low temperature monobloc
4P522035-1 – 2018.01

To configure the holiday (when you stay at home)

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [2.2]: 

 > Holiday > Holiday mode.

2

Select Home.

3

Configure the holiday mode settings (when you stay at home).

4

Activate the holiday mode.

Possible holiday mode settings (when you stay at home)

Setting

Description

From and Until

First and last day of your holiday.

Use day
schedule

Day schedule used during your holiday.

Example: 

Saturday

INFORMATION

Switch to Adv. end user if you want to change the Use day
schedule setting.

To configure the holiday (when you go away)

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [2.2]: 

 > Holiday > Holiday mode.

2

Select Leave.

3

Configure the holiday mode settings (when you go away).

4

Activate the holiday mode.

Possible holiday mode settings (when you go away)

Setting

Description

From and Until

First and last day of your holiday.

Operation mode Operation mode used during your holiday.

Heating

Set point used during your holiday when the unit
is operating in heating mode.

Cooling

Set point used during your holiday when the unit
is operating in cooling mode.

DHW

Turn ON or OFF domestic hot water operation
during your holiday.

INFORMATION

You  can  only  change  the  From  and  Until  settings  in  the
End  user  level.  For  changing  the  other  settings,  you  have
to switch to Adv. end user level.

To activate or deactivate the holiday mode

Prerequisite: 

You have configured the holiday.

1

Go to [2.1]: 

 > Holiday > Holiday.

2

Do one of the following:

▪ To activate, select Yes and press 

.

▪ To deactivate, select No and press 

.

Usage example: You go away during the winter

If you are in the following situation:

▪ In 2 days, you go away for 2 weeks during the winter.

▪ You want to save energy, but prevent your house from freezing.

Then you can do the following:

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Configure  the  holiday.  Go  to  [2]: 

  >  Holiday,  and  configure

the following settings:

Setting

Value

Holiday mode

Away

Setting

Value

From

2 February 2014

Until

16 February 2014

Operation mode

Heating

Heating

12°C

2

Activate the holiday mode.

▪ Go to [2.1]: 

 > Holiday > Holiday.

▪ Select Yes and press 

.

Advantage:

▪ Before and after your holiday, your normal schedule will be used.

▪ During  your  holiday,  you  save  energy  and  prevent  your  house

from freezing.

Usage example: You come home during your holiday

If you are in the following situation:

▪ You configured and activated the holiday mode (Away).

▪ During your holiday, you come home for a few hours and want to

use your normal schedule.

Then you can do the following:

1

Deactivate the holiday mode.

2

When you go away again, activate the holiday mode again.

Advantage:

You do NOT have to change your schedule or holiday configuration.

4.6.4

Reading out information

To read out information

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [6]: 

 > Information.

Possible read-out information

In menu…

You can read out…

[6.1] Sensor information

Room, tank or DHW, outside,
and leaving water temperature.
(If applicable)

[6.2] Energy metering

Produced energy, consumed
electricity, and consumed gas.

[6.3] Error handling

Error history and contact/
helpdesk number.

[6.4] User permission level

Current user permission level.

[6.5] Actuators

Status/mode of each actuator.

Example: 

Domestic hot water

pump ON/OFF.

[6.6] Operation modes

Current operation mode.

Example: 

Defrost/oil return

mode.

[6.7] Running hours

Running hours of the system.

[6.8] Version

Version information about the
system.

INFORMATION

If glycol is present in the system, then the produced energy
will NOT be displayed.

4.6.5

Configuring date, time, units of
measurement, contrast and backlight

To configure time and date

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

Содержание Altherma EBLQ016CAV3

Страница 1: ...English User reference guide Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 EDLQ011CAW1 EDLQ014CA...

Страница 2: ...g and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water temperature main 18 4 7 5 Predefined schedules Leaving water temperature additional...

Страница 3: ...ive consequences for the environment and human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NO...

Страница 4: ...Space heating cooling control How to control space heating cooling Setting the space operation mode Controlling the temperature Domestic hot water control How to control domestic hot water Reheat mode...

Страница 5: ...e User permission level Installer Defrost oil return mode is active Hot start mode is active Emergency operation is active 4 3 Basic usage 4 3 1 Using home pages About home pages You can use the home...

Страница 6: ...down a space You have to tell the system which space operation mode to use Heating only The system can heat up a space but NOT cool down a space You do NOT have to tell the system which space operatio...

Страница 7: ...water temperature control 3 Only for room thermostat control Go to the main leaving water temperature home page LWT main and check the following Is displayed next to the set point Then leaving water s...

Страница 8: ...The mode will return to Scheduled according to the overrule period Example Temporarily overruling the schedule AND changing the mode to preset value You have configured the following settings Setting...

Страница 9: ...3 hours Then you can do the following 1 Set the overrule period Temperature lock to 2 hours 2 Go to the room temperature home page Room 3 Press to select Result For the next 2 hours the room will NOT...

Страница 10: ...rol Leaving water temperature control means that you only control the leaving water temperature To control the leaving water temperature you can do the following You can Location Read out the desired...

Страница 11: ...Advice In order to avoid unsuccessful disinfection function at least allow the booster heater by the weekly program for minimum 4 hours starting from the scheduled start up of disinfection If the boos...

Страница 12: ...hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water to a preset value example Storage eco 50 C Hot water is available again During the afternoon a...

Страница 13: ...e sufficient hot water comfortable You do NOT have to change the schedule easy You do NOT have to activate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW t...

Страница 14: ...ensure the heating cooling capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission...

Страница 15: ...during the winter You want to save energy but prevent your house from freezing Then you can do the following Prerequisite You switched the permission level to Advanced end user 1 Configure the holida...

Страница 16: ...pages that are possible for your system layout are listed 2 Select a home page and press 3 Do one of the following To display the home page select Yes and press To hide the home page select No and pre...

Страница 17: ...and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user defined schedule 3 Change it 4 Save it Guidelines when programming 07 00 Set heating schedul...

Страница 18: ...6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desired DHW tank...

Страница 19: ...igher than d as for low outdoor temperatures warmer water is required In cooling this value should be higher than d as for low outdoor temperatures less cold water suffices d Desired leaving water tem...

Страница 20: ...rs Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock...

Страница 21: ...oling interruption will happen when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only in case of a domestic hot water tank without an internal booster heater INFORMATION When the DHW tank boo...

Страница 22: ...58 Electricity 12 49 pence kWh 7 4 5 17 49 6 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWA...

Страница 23: ...ion Error handling Error history 8 3 To check the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 8 4 Symptom You...

Страница 24: ...ving water temperature Water temperature at the water outlet of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the pro...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...4P522035 1 2018 01 Copyright 2018 Daikin...

Отзывы: