2 Components
Service manual
64
EBLQ+EDLQ011~W1 + EBLQ+EDLQ011~0W1
+ EK(2)CB EKMB9W1
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02
9
Press the switch BS3 once. The LED status should be as
follows:
a
b
c
d
e
f
g
10
Press the switch BS2 once. The LED status should be as
follows:
a
b
c
d
e
f
g
11
Press the switch BS3 once. The LED status should be as
follows:
a
b
c
d
e
f
g
12
Press the switch BS3 once. The LED status should be as
follows:
a
b
c
d
e
f
g
13
All LED’s on the Inverter Analyzer must lit.
14
Turn off the respective circuit breaker.
15
Wait a few minutes and confirm that the LED’s of the Inverter
Analyzer are off.
16
Disconnect the Inverter Analyzer from the Faston connectors.
17
Connect the Faston connectors to the wire terminals U, V and
W of the compressor.
INFORMATION
Use the notes made during disconnection to connect the
Faston connectors to the correct wire terminals of the
compressor.
All LED’s of the inverter
analyzer are lit during inverter
test?
Action
Yes
Return to
inverter PCB and continue with
the next procedure.
No
Replace the inverter PCB, see
Problem solved?
After all checking procedures listed above have been performed:
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Repair procedures
To remove the inverter PCB
Prerequisite:
Turn OFF the unit via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Disconnect all connectors from the main PCB.
2
Remove the cable booms that surround the main PCB.
b
c
c
d
a
a
f
f
a
e
a
Main PCB cable boom
b
Main PCB
c
Cable clamp screw
d
Ground wire screw
e
Main PCB mounting plate
f
Main PCB mounting screw
3
Loosen and remove the 2 screws that fix the cable clamps.
4
Loosen and remove the screw that fixes the ground wire.
5
Disconnect the fan connectors.
6
Loosen and remove the 2 screws that fix the main PCB
mounting plate.
7
Disconnect all connectors from the inverter PCB.
c
c
c
b
a
e
d
a
Inverter PCB
b
Compressor cable
c
Inverter PCB cable boom
d
Inverter PCB screw
e
Inverter PCB mounting plate
8
Unplug all Faston connectors from the inverter PCB.
9
Cut the tie straps at the rear of the main PCB mounting plate to
improve manoeuvrability of the main PCB mounting plate.
10
Lift the main PCB mounting plate and place it on a support.
Содержание Altherma EBLQ011CAV3