8 Relocation

User reference guide

22

EA23DA6V(7)+9W

Daikin Altherma 3 H F

4P556076-1A – 2021.09

▪ When  auto  emergency  is  set  to 

Automatic

  and  a  heat  pump

failure  occurs,  the  backup  heater  will  automatically  take  over  the
heat load and the domestic hot water production.

▪ When  auto  emergency  is  set  to 

Manual

  and  a  heat  pump  failure

occurs,  the  domestic  hot  water  and  space  heating  operation  will
stop and need to be recovered manually via the user interface. To
recover  operation  manually,  go  to  the 

Malfunctioning

  main

menu screen, where the user interface will then ask you to confirm
whether the backup heater can take over the heat load or not.

When  the  heat  pump  fails, 

  or 

  will  appear  on  the  user

interface.

Possible cause

Corrective action

Heat pump is damaged.

See 

"7.1 To display the help text

in case of a malfunction"

 [

4

 21].

INFORMATION

When  the  backup  heater  takes  over  the  heat  load,
electricity consumption will be considerably higher.

7.6

Symptom: The system is making
gurgling noises after
commissioning

Possible cause

Corrective action

There is air in the system.

Purge air from the system.

(a)

Incorrect hydraulic balance.

To be performed by the installer:

1

Perform  hydraulic  balancing
to  assure  that  the  flow  is
correctly 

distributed

between the emitters.

2

If  hydraulic  balancing  is  not
sufficient,  change  the  pump
limitation  settings  ([9-0D]
and [9-0E] if applicable).

Various malfunctions.

Check if 

 or 

 is displayed

on the home screen of the user
interface. See 

"7.1 To display the

help text in case of a
malfunction"

 [

4

 21] for more

information about the
malfunction.

(a)

We recommend to purge air with the air purge function of the unit
(to be performed by the installer). If you purge air from the heat
emitters or collectors, mind the following:

WARNING

Air  purging  heat  emitters  or  collectors.

  Before  you

purge  air  from  heat  emitters  or  collectors,  check  if 

  or

 is displayed on the home screen of the user interface.

▪ If not, you can purge air immediately.

▪ If  yes,  make  sure  that  the  room  where  you  want  to

purge air is sufficiently ventilated. 

Reason:

 Refrigerant

might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.

8

Relocation

8.1

Overview: Relocation

If  you  want  to  relocate  parts  of  your  system,  contact  your  installer.
You can find the contact/helpdesk number via the user interface.

9

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

10

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the unit.

Dealer

Sales distributor for the product.

Authorised installer

Technical  skilled  person  who  is  qualified  to  install  the
product.

User

Person  who  is  owner  of  the  product  and/or  operates  the
product.

Applicable legislation

All  international,  European,  national  and  local  directives,
laws,  regulations  and/or  codes  that  are  relevant  and
applicable for a certain product or domain.

Service company

Qualified  company  which  can  perform  or  coordinate  the
required service to the product.

Installation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to install, configure and maintain
it.

Operation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to operate it.

Accessories

Labels, manuals, information sheets and equipment that are
delivered  with  the  product  and  that  need  to  be  installed
according  to  the  instructions  in  the  accompanying
documentation.

Optional equipment

Equipment  made  or  approved  by  Daikin  that  can  be
combined  with  the  product  according  to  the  instructions  in
the accompanying documentation.

Field supply

Equipment NOT made by Daikin that can be combined with
the  product  according  to  the  instructions  in  the
accompanying documentation.

Содержание Altherma EAVZ16S18DA9W

Страница 1: ...User reference guide Daikin Altherma 3 H F English User reference guide Daikin Altherma 3 H F EAVZ16S18DA6V 7 EAVZ16S23DA6V 7 EAVZ16S18DA9W EAVZ16S23DA9W ...

Страница 2: ...on 21 7 2 To check the malfunction history 21 7 3 Symptom You are feeling too cold hot in your living room 21 7 4 Symptom The water at the tap is too cold 21 7 5 Symptom Heat pump failure 21 7 6 Symptom The system is making gurgling noises after commissioning 22 8 Relocation 22 8 1 Overview Relocation 22 9 Disposal 22 10 Glossary 22 1 About this document Thank you for purchasing this product Pleas...

Страница 3: ... situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the installation and operation manual and the wiring instruction sheet Before performing maintenance and service tasks read the service manual For more information see the installer and user reference guide The...

Страница 4: ...gerant inside this unit is mildly flammable WARNING The appliance shall be stored so as to prevent mechanical damage and in a well ventilated room without continuously operating ignition sources example open flames an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting proc...

Страница 5: ... of a malfunction 421 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the screens menus and settings of the LCD screen To set values a b c d e Item Description a Left dial T...

Страница 6: ...tanding indoor unit with integrated tank b2 Water pressure Space operation mode c Cooling only with EKHVCONV2 installed Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Current date and time Holiday f Holiday mode active Main zone g3 g1 g4 g2 g1 Heat emitter type Underfloor heating Fancoil unit Radiator g2 Leaving water temperature setpoint g3 Room the...

Страница 7: ...ccess to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation Turn heating cooling functionality and domestic hot water preparation on or off 4 2 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature scr...

Страница 8: ...operation to On or Off Tank heating operation NOTICE Disinfection mode Even if you turn OFF tank heating operation C 3 Operation Tank disinfection mode will remain active However if you turn it OFF while disinfection is running an AH error occurs 1 Go to C 3 Operation Tank Operation Tank Off On Space heating cooling C 3 2 Set operation to On or Off 4 4 Space heating cooling control 4 4 1 About spa...

Страница 9: ...ximately 5 seconds While the unit is in operation the status indicator will light up blue constantly To set the space operation mode 1 Go to 4 1 Space heating cooling Operation mode 2 Select one of the following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per m...

Страница 10: ...r temperature b Desired leaving water temperature If scheduling is on after changing the desired leaving water temperature The temperature will stay the same as long as there is no scheduled action The desired leaving water temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off leaving wa...

Страница 11: ...temperature t Time Initially the DHW tank temperature is the same as the temperature of the domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water to a preset value example...

Страница 12: ...rowse through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed Advanced user pin code The Advanced user pin code is 1234 Additional menu items for the user are now visible 1234 Advanced user User pin code The User pin code is 0000 0000 User 4 6 1 Using quiet mode About quiet mode You can use quiet mode to decrease the sound of the...

Страница 13: ...stat and the LAN adapter 4 6 4 To configure time and date 1 Go to 7 2 User settings Time date 4 7 Preset values and schedules 4 7 1 Using preset values About preset values For some settings in the system you can define preset values You only need to set these values one time then reuse the values in other screens such as the scheduling screen If you later want to change the value you only have to ...

Страница 14: ...gy Calculate the value for the electricity price with following formula Actual electricity price Incentive kWh For the procedure to set the electricity price see To set the electricity price 414 Example This is an example and the prices and or values used in this example are NOT accurate Data Price kWh Gas price 4 08 Electricity price 12 49 Data Price kWh Renewable heat incentive per kWh 5 Calcula...

Страница 15: ...he DHW mode is one of the following Schedule only Schedule reheat Possible actions Comfort When to start heating the tank to the user defined preset value 5 2 Comfort setpoint Eco When to start heating the tank to the user defined preset value 5 3 Eco setpoint Stop When to stop heating the tank even if the desired tank temperature is not reached yet Note In Schedule reheat mode the system also tak...

Страница 16: ...me as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Select Monday Mon Sat Wed Fri Thu Tue Sun User d...

Страница 17: ...2 Setpoint X2 Y1 Example Y1 Y2 X1 X2 a Possible actions on this screen Go through the temperatures Change the temperature Go to the next temperature Confirm changes and proceed 4 8 3 Slope offset curve 4 8 4 Using weather dependent curves Configure weather dependent curves as following To define the setpoint mode To use the weather dependent curve you need to define the correct setpoint mode Go to...

Страница 18: ...t To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dependent curve of a zone or tank You feel Fine tune with slope and offset At regular outdoor temperatures At cold outdoor temperatures Slope Offset OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot To fine tune the weather dependent curve 2 points curve The foll...

Страница 19: ...Schedule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B User profile C Operation Room Space heating cooling Tank 1 4 Antifrost Activation Room setpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time d...

Страница 20: ...rature In heating mode a lower desired leaving water temperature results in lower energy consumption and better performance Set the desired leaving water temperature in accordance with the heat emitter type Example Underfloor heating is designed for lower leaving water temperature than radiators and heat pump convectors Tips about DHW tank temperature Use a weekly schedule for your normal domestic...

Страница 21: ...is displayed on the screen 7 2 To check the malfunction history Conditions The user permission level is set to advanced end user 1 Go to 8 2 Information Malfunction history You see a list of the most recent malfunctions 7 3 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temper...

Страница 22: ...ce If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently ventilated Reason Refrigerant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact help...

Страница 23: ......

Страница 24: ...4P556076 1A 2021 09 Copyright 2018 Daikin Verantwortung für Energie und Umwelt ...

Отзывы: