3
|
Operation
User reference guide
45
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1 – 2019.10
slope of the curve depends on local circumstances such as climate and the
insulation of the house, the curve can be adjusted by an installer or user.
Availability
The weather-dependent curve is available for:
▪
Main zone - Heating
▪
Additional zone - Heating
▪
Tank
INFORMATION
To operate weather dependent, correctly configure the setpoint of the main zone,
additional zone or tank. See
"3.8.3 Using weather-dependent curves"
45].
3.8.2 2-points curve
Define the weather-dependent curve with these two setpoints:
▪
Setpoint (X1, Y2)
▪
Setpoint (X2, Y1)
Example
Set weather-dependent heating
Confirm
Adjust
Scroll
T
t
T
a
X1
Y1
Y2
X2
X1, X2
Examples of outdoor ambient temperature
Y1, Y2
Examples of desired tank temperature or leaving water temperature
3.8.3 Using weather-dependent curves
Configure weather-dependent curves as following:
To define the setpoint mode
To use the weather-dependent curve, you need to define the correct setpoint
mode:
Go to setpoint mode …
Set the setpoint mode to …
Main zone – Heating
[A.3.1.1.1]
Main
>
LWT setpoint
mode
Weather dep.
OR
WD/scheduled
Additional zone – Heating
[A.3.1.2.1]
Additional
>
LWT
setpoint mode
Weather dep.
OR
WD/scheduled
Tank
[A.4.6]
Domestic hot water (DHW)
>
SP mode
Weather dep.