7
|
Unit installation
Installer reference guide
89
ERLA11~W1 + EBSH/X(B)11+16P30+50DF
Daikin Altherma 3 R ECH₂O
4P663482-1A – 2021.11
Typical workflow
Mounting the indoor unit typically consists of the following stages:
1
Installing the indoor unit.
7.4.2 Precautions when mounting the indoor unit
INFORMATION
Also read the precautions and requirements in the following chapters:
▪
"2 General safety precautions"
▪
"7.1 Preparing the installation site"
7.4.3 To install the indoor unit
1
Lift the indoor unit from the pallet and place it on the floor. Also see
2
Connect the drain hose to the drain. See
"7.4.4 To connect the drain hose to
89].
3
Slide the indoor unit into position.
NOTICE
Level.
Make sure the unit is level.
7.4.4 To connect the drain hose to the drain
Spillover water from the water storage tank as well as water collecting in the drain
pan must be drained. You must connect the drain hoses to an appropriate drain
according to the applicable legislation.
1
Open the screw plug.
a
a
c
c
b
1
3
2
a
Screw plug
b
Assembly wrench
c
Spillover connector
2
Insert the spillover connector into the screw plug.
3
Mount the spillover connector.
4
Attach a drain hose to the spillover connector.
5
Connect the drain hose to an appropriate drain. Ensure the water can flow
through the drain hose. Ensure that the water level cannot mount above the
overspill.
6
Connect the drain pan hose to the drain pan connection and connect to an
appropriate drain.