4 Installation
Installation manual
14
EAV23DA6V
Daikin Altherma 3 H F
4P606486-1 – 2019.12
4.4.9
To connect the space cooling/heating ON/
OFF output
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models
▪ Heating only conversion kit (EKHVCONV2)
1
Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
X1M
X2M
A4P
X5M
X1M
YC
Y1
Y2
Y3
Y4
YC
Y2
a
7 9
b
a
Installation of EKRP1HBAA is required.
b
Prewiring between X2M/7+9 and Q1L (= thermal
protector backup heater). Do NOT change.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.10
To connect the changeover to external
heat source
1
Connect the changeover to external heat source cable to the
appropriate terminals as shown in the illustration below.
X1M
X2M
A4P
X5M
X1M
YC
Y1
Y2
Y3
Y4
X2 X1
X2M
X4 X3
N L
a
a
Installation of EKRP1HBAA is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.11
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.
X1M
X2M
A8P
X5M
1 2 3 4 5
X801M
S6S
S7S
S8S
S9S
a
a
Installation of EKRP1AHTA is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.12
To connect the safety thermostat
(normally closed contact)
1
Connect the safety thermostat (normally closed) cable to the
appropriate terminals as shown in the illustration below.
X1M
X2M
X5M
9 10
2
Fix the cable with cable ties to the cable tie mountings.
NOTICE
Make sure to select and install the safety thermostat
according to the applicable legislation.
In any case, to prevent unnecessary tripping of the safety
thermostat, we recommend the following:
▪ The safety thermostat is automatically resettable.
▪ The safety thermostat has a maximum temperature
variation rate of 2°C/min.
▪ There is a minimum distance of 2 m between the safety
thermostat and the 3‑way valve.
INFORMATION
ALWAYS configure the safety thermostat after it is
installed. Without configuration, the indoor unit will ignore
the safety thermostat contact.
INFORMATION
The preferential kWh rate power supply contact is
connected to the same terminals (X5M/9+10) as the safety
thermostat. Thus, the system can have EITHER
preferential kWh rate power supply OR a safety
thermostat.