3 About the box
Installation manual
5
EGSAH/X06+10UD
Daikin Altherma 3 GEO
4P598591-1C – 2023.02
3.1
Indoor unit
INFORMATION
This unit has been tested and approved according to
BS EN12897:2016
3.1.1
To remove the accessories from the
indoor unit
1×
a
1×
d
1×
c
1×
i
1×
j
1×
k
1×
l
1×
e
1×
g
1×
b
4×
f
ENERG
IJA
Y
IA
IE
ENERG
IJA
Y
IA
IE
1×
h
a
Shut-off valve with integrated filter
b
Safety valve (connection parts for mounting on top of
brine level vessel included)
c
Brine level vessel
d
Remote outdoor sensor (with installation manual)
e
Cable for remote outdoor sensor (40 m)
f
O-rings (spares for hydro module shut-off valves)
g
Tundish
h
Energy label
i
General safety precautions
j
Addendum book for optional equipment
k
Installation manual
l
Operation manual
3.1.2
To handle the indoor unit
Mind the following guidelines when handling the unit:
>200
kg
▪ Use a trolley to transport the unit. Make sure to use a trolley with a
sufficiently long horizontal ledge, suitable for transportation of
heavy appliances.
▪ When transporting the unit, keep the unit upright.
▪ Use the handles at the back to carry the unit.
▪ Remove the hydro module before you carry the unit up or down
staircases. See
"4.2.2 To remove the hydro module from the
7].
▪ It is recommended to use lifting straps to carry the unit up or down
staircases.
3.2
Domestic hot water tank kit
3.2.1
To remove the accessories from the
domestic hot water tank kit
d
b
a
c
e
g
f
a
Pressure reducing valve/pressure relief valve
combination. Water inlet and water outlet 22 mm
connection, discharge piping connection 15 mm
b
Adaptor 22 mm×3/4" Female BSP
c
T-piece 22 mm×22 mm×22 mm
d
Tundish 15 mm inlet, 22 mm outlet
e
Wall mounting set for expansion vessel
f
Instruction sheet
g
Expansion vessel of 18 l – 3/4" Male BSP
NOTICE
All piping MUST be installed according to section G3 of the
Building Regulations.
3.3
Checklist for the required DHW
accessories
For installation compliant with section G3 of the Building
Regulations, you must verify that the following accessories are
present.
Delivered with indoor unit:
Tundish 15 mm inlet, 22 mm outlet
Delivered with domestic hot water tank kit:
Pressure reducing valve/pressure relief valve combination
Adaptor 22 mm×3/4" Female BSP
T-piece 22 mm×22 mm×22 mm
Tundish 15 mm inlet, 22 mm outlet