background image

3 Operation

Operation manual

5

EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569812-1 – 2019.02

Item

Description

j

Malfunction

A malfunction occurred.

See 

"6.1 To display the help text in case of a

malfunction" on page 11

 for more information.

(1)

If the corresponding operation (for example: space heating)
is not active, the circle is greyed out.

3.2.2

Main menu screen

In the home screen, press 

 to open the main menu screen.

From the main menu, you can access the different setpoint screens
and submenus.

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Item

Description

 or 

Malfunctioning

Restriction: 

Only displayed if a malfunction

occurs.

See 

"6.1 To display the help text in case of

a malfunction" on page 11

 for more

information.

 

Room

Restriction: 

Only displayed if a dedicated

Human Comfort Interface (BRC1HHDA
used as room thermostat) is controlling the
indoor unit.

Set the room temperature.

 

Main zone

Shows the applicable symbol for your main
zone emitter type.

Set the leaving water temperature for the
main zone.

 

Additional zone

Restriction: 

Only displayed if there are two

leaving water temperature zones. Shows
the applicable symbol for your additional
zone emitter type.

Set the leaving water temperature for the
additional zone.

 

Space heating/

cooling

Restriction: 

Only for heating/cooling

models.

Shows the applicable symbol of your unit.
Put the unit in heating mode or cooling
mode.

 

Tank

Set the domestic hot water tank
temperature.

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

 

Information

Displays data and information about the
indoor unit.

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

 

User profile

Change the active user profile.

Item

Description

 

Operation

Turn heating/cooling functionality and
domestic hot water preparation on or off.

3.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Example:

▪ Room temperature screen

▪ Main zone screen

▪ Additional zone screen

▪ Tank temperature screen

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

3.2.4

Detailed screen with values

a

b

a

Settings

b

Values

Possible actions on this screen

Go through the list of settings.

Change the value.

Go to the next setting.

Confirm changes and proceed.

3.3

Space heating/cooling control

3.3.1

Setting the space operation mode

To set the space operation mode

1

Go to [4.1]: 

Space heating/cooling

 > 

Operation

mode

Содержание Altherma 3 GEO EGSAH06DA9W

Страница 1: ...Operation manual Daikin Altherma 3 GEO English Operation manual Daikin Altherma 3 GEO EGSAH06DA9W EGSAH10DA9W EGSAX06DA9W G EGSAX10DA9W G ...

Страница 2: ...eep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you must read before installing Format Paper in the box of the unit Operation manual Quick guide for basic usage Format Paper in the box of the unit User reference guide Detailed step by ...

Страница 3: ...icator b LCD screen c Dials and buttons Status indicator The LEDs of the status indicator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occurred See 6 1 To display the help text in case of a malfunction on page 11 for more info...

Страница 4: ...5 Measured tank temperature 1 b Current date and time c Disinfection Powerful Disinfection mode active Powerful operation mode active d Space operation mode Cooling Heating e Outdoor quiet mode e1 6 Measured outdoor temperature 1 e2 Quiet mode active e3 Outdoor brine piping f Indoor unit domestic hot water tank f1 Floor standing indoor unit with integrated tank f2 Water pressure g Main zone g1 Ins...

Страница 5: ...de or cooling mode Tank Set the domestic hot water tank temperature User settings Gives access to user settings such as holiday mode and quiet mode Information Displays data and information about the indoor unit Installer settings Restriction Only for the installer Gives access to advanced settings Commissioning Restriction Only for the installer Perform tests and maintenance User profile Change t...

Страница 6: ...r temperature is set by your installer in accordance with the heat emitter type Only adjust the leaving water temperature settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the se...

Страница 7: ...ditional menu items for the user are now visible 3 6 Schedule screen Example This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules are similar To program the schedule Example You want to program the following schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 Prerequisite The room temperature schedule is o...

Страница 8: ...ue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24...

Страница 9: ...g Operation mode Operation mode schedule 5 Tank Powerful operation Comfort setpoint Eco setpoint Reheat setpoint Schedule WD curve type 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B User profile C Operation Room Space heating cool...

Страница 10: ...e Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Example When you stay at home during your holiday or when you go away during your holiday Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Comfort higher D...

Страница 11: ...e 6 Possible cause Corrective action The weather dependent curve is set incorrectly Adjust the weather dependent curve See the user reference guide 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of unusual high consumption If you immediately need domestic hot water activate the DHW tank Powerful operation However this consume...

Страница 12: ... collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently ventilated Reason Refrigerant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 7 Disposal NOTICE Do NOT try to dismantle the system yourse...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...4P569812 1 2019 02 Copyright 2019 Daikin 4P569812 1 0000000T ...

Отзывы: