![Daikin ADEA35A2VEB Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/daikin/adea35a2veb/adea35a2veb_user-reference-manual_3707956007.webp)
8 Troubleshooting
User reference guide
7
ADEA35~125A2VEB
Split system air conditioners
4P551388-1 – 2018.09
Clean with a soft cloth. If it is difficult to remove stains, use water or
neutral detergent.
7.4.2
To clean the air filter
When to clean the air filter
:
▪ Rule of thumb: Clean every 6 months. If the air in the room is
extremely contaminated, increase the cleaning frequency.
▪ Depending on the settings, the user interface can display the
TIME TO CLEAN AIR FILTER
notification. Clean the air filter
when the notification is displayed.
▪ If the dirt becomes impossible to clean, change the air filter
(= optional equipment).
How to clean the air filter
:
1
Remove the air filters by pulling their cloth upward (in case of
rear suction) or backward (in case of bottom suction).
rear suction
bottom suction
2
Clean the air filter. Use a vacuum cleaner or wash with water. If
the air filter is very dirty, use a soft brush and neutral detergent.
3
Dry the air filter in the shadow.
4
Reattach the air filter. Align the 2 hanger brackets and push the
2 clips in their place and pull the cloth if necessary.
rear suction
bottom suction
5
Confirm that 4 hangers are fixed.
6
In case of bottom suction, close the air inlet grille.
7
Turn ON the power.
8
Press the
FILTER SIGN RESET
button.
Result:
The
TIME TO CLEAN AIR FILTER
notification disappears
from the user interface.
7.5
Maintenance before a long stop
period
E.g., at the end of the season.
▪ Let the indoor units run in fan only operation for about half a day in
order to dry the interior of the units.
▪ Turn off the power. The user interface display disappears. When
the main power is turned on, the air conditioner will use some
power, even if it is not operating.
▪ Clean air filters and casings of indoor units. Contact your installer
or maintenance person to clean air filters and casings of the
indoor unit. Maintenance tips and procedures for cleaning are
provided in the installation/operation manuals of dedicated indoor
units. Make sure to install cleaned air filters back in the same
position.
7.6
Maintenance after a long stop
period
E.g., at the beginning of the season.
▪ Check and remove everything that might be blocking inlet and
outlet vents of indoor units and outdoor units.
▪ Check if the earth is connected properly.
▪ Check if there is somewhere a broken wire. Contact your dealer in
case of problems.
▪ Clean air filters and casings of indoor units. Contact your installer
or maintenance person to clean air filters and casings of the
indoor unit. Maintenance tips and procedures for cleaning are
provided in the installation/operation manuals of dedicated indoor
units. Make sure to install cleaned air filters back in the same
position.
▪ Turn on the power at least 6 hours before operating the unit in
order to ensure smoother operation. As soon as the power is
turned on, the user interface display appears.
8
Troubleshooting
If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
WARNING
Stop operation and shut off the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electric shock or fire. Contact your dealer.
The system MUST be repaired by a qualified service person.
Malfunction
Measure
If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.
Turn OFF the main power
switch.
If water leaks from the unit.
Stop the operation.
The operation switch does NOT work
well.
Turn OFF the power
supply.
If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.
Notify your installer and
report the malfunction
code.
If the system does NOT properly operate except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system according to the following
procedures.