• Outdoor Unit • AZQS-BV1
2
• Split - Sky Air • AZQS-BV1
6
2
Specifications
Notes
(1) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A
and
≤
75A per phase.
(2) Short-circuit power
(3) RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
(5) See separate drawings for electrical data
(6) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents
produced by equipment connected to public low-voltage systems with input current \>16A and
≤
75A per phase
(7) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
2-5 Electrical Specifications
AZQS71BV1
AZQS100BV1
AZQS125BV1
AZQS140BV1
Power supply
Name
V1
Phase
1~
Frequency
Hz
50
Voltage
V
220-240
Voltage range
Min.
%
-10
Max.
%
10
Current
Nominal running
current (RLA)
Cooling
A
16.20
-
Zmax
List
Complies to EN6100-3-
3
Complies to EN61000-3-12
Recommended fuses
A
20
32
Current - 50Hz
Maximum fuse amps (MFA)
A
20
-
Current - 60Hz
Maximum fuse amps (MFA)
A
-
Wiring connections
For power supply
Remark
-
See installation manual outdoor unit
For connection with
indoor
Remark
-
See installation manual outdoor unit
Power supply intake
Outdoor unit only
Содержание ABQ100C/AZQS100BV1
Страница 1: ...Air Conditioning Technical Data EEDEN14 131A AZQS BV1 ...
Страница 2: ......
Страница 10: ... Outdoor Unit AZQS BV1 4 Split Sky Air AZQS BV1 8 4 Options 4 1 Options ...
Страница 12: ... Outdoor Unit AZQS BV1 6 Split Sky Air AZQS BV1 10 6 Capacity tables 6 1 Cooling Capacity Tables ...
Страница 13: ...3 6 Split Sky Air AZQS BV1 11 Outdoor Unit AZQS BV1 6 Capacity tables 6 2 Heating Capacity Tables ...
Страница 17: ...3 6 Split Sky Air AZQS BV1 15 Outdoor Unit AZQS BV1 6 Capacity tables 6 4 Capacity Correction Factor ...
Страница 18: ... Outdoor Unit AZQS BV1 7 Split Sky Air AZQS BV1 16 7 Dimensional drawings 7 1 Dimensional Drawings ...
Страница 19: ...3 7 Split Sky Air AZQS BV1 17 Outdoor Unit AZQS BV1 7 Dimensional drawings 7 1 Dimensional Drawings ...
Страница 20: ... Outdoor Unit AZQS BV1 8 Split Sky Air AZQS BV1 18 8 Centre of gravity 8 1 Centre of Gravity ...
Страница 21: ...3 8 Split Sky Air AZQS BV1 19 Outdoor Unit AZQS BV1 8 Centre of gravity 8 1 Centre of Gravity ...
Страница 22: ... Outdoor Unit AZQS BV1 9 Split Sky Air AZQS BV1 20 9 Piping diagrams 9 1 Piping Diagrams ...
Страница 23: ...3 10 Split Sky Air AZQS BV1 21 Outdoor Unit AZQS BV1 10 Wiring diagrams 10 1 Wiring Diagrams Single Phase ...
Страница 24: ... Outdoor Unit AZQS BV1 10 Split Sky Air AZQS BV1 22 10 Wiring diagrams 10 1 Wiring Diagrams Single Phase ...
Страница 25: ...3 11 Split Sky Air AZQS BV1 23 Outdoor Unit AZQS BV1 11 Sound data 11 1 Sound Power Spectrum ...
Страница 26: ... Outdoor Unit AZQS BV1 11 Split Sky Air AZQS BV1 24 11 Sound data 11 2 Sound Pressure Spectrum Cooling ...
Страница 27: ...3 11 Split Sky Air AZQS BV1 25 Outdoor Unit AZQS BV1 11 Sound data 11 3 Sound Pressure Spectrum Heating ...
Страница 28: ... Outdoor Unit AZQS BV1 11 Split Sky Air AZQS BV1 26 11 Sound data 11 4 Sound Pressure Spectrum Quiet Mode ...
Страница 29: ...3 12 Split Sky Air AZQS BV1 27 Outdoor Unit AZQS BV1 12 Installation 12 1 Installation Method ...
Страница 30: ... Outdoor Unit AZQS BV1 12 Split Sky Air AZQS BV1 28 12 Installation 12 1 Installation Method ...
Страница 32: ......