Four Way Valve
Si121293EC
20
Removal Procedure
2
Remove the terminal
cover.
3
Unfasten the hook with
a flat screwdriver and
remove the overload
protector.
4
5
Disconnect the
terminals of the
compressor harness.
Remove the bushing for
the lead wire.
U: red
V: yellow
W: blue
2. Remove the four way
valve.
1
2
Heat up the brazed
parts in order of (a) (b)
(c) (d).
Remove the four way
valve.
Step
Procedure
Points
Terminal cover
(R18010)
Overload protector
Hook
(R24005)
Compressor harness
Bushing for lead wire
(R18007)
(a)
(b)
(c)
(d)
(R22553)