Si12-996
Removal of Outer Panels
Removal Procedure
5
3
Remove the front panel
(2).
The insulation sheet is
inserted between the front
panel (2) and the electrical
box.
5. Removal of the front
panel (1)
Remove the discharge grille
and outdoor fan first to
remove the front panel (1).
1
Remove the 4 screws
on the discharge grille.
2
Pull the bottom of the
discharge grille toward
yourself.
Step
Procedure
Points
(R11056)
Insulation sheet
(R11057)
Discharge grille
Front panel (1)
(R11058)