Si121091
Removal of Damper Motor
Removal Procedure
9
3. Removal of Damper Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Removal of the damper
motor
Disconnect the connector
for the humidifying rotor
motor. (Refer to page 8.)
1
Disconnect the
connector for the
damper motor.
(R10348)
Harness ASSY
Damper
motor
Humidifying thermistor
(R0232)