Four Way Valve
Si121561E
22
Removal Procedure
2
Remove the terminal
cover.
3
4
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
5
6
Remove the putty.
Heat up the 4 brazed
parts and remove the
four way valve.
Step
Procedure
Points
Terminal
cover
(R22503)
U (red)
V (yellow)
W (blue)
Protection bushing
Overload
protector
(R22504)
Four way valve
Putty
Brazed part