10 Commissioning
Installation manual
17
2MXM-A, 3MXM-A, 4MXM-A, 5MXM-A
R32 Split series
3P600450-6M – 2021.12
E
D
C
B
A
E
D
C
B
A
A
1
2
3
4
5
SW4
OFF
ON
2
1×
1
3
Reset the power.
9.3
About night quiet mode
The night quiet mode function makes the outdoor unit run more
quietly at nighttime. This will reduce the cooling capacity of the unit.
Explain Night quiet mode to the customer and confirm if customer
wants to use this mode.
9.3.1
To turn ON the night quiet mode
1
Remove the switch cover on the service PCB.
1×
1
2
1
A
1
2
3
4
5
SW6
2
OFF
ON
2
1
2
Set the night quiet mode switch (SW6-1) to ON.
9.4
About heat mode lock
Heat mode lock limits the unit to heat operation.
9.4.1
To turn ON heat mode lock
1
Remove the switch cover on the service PCB.
2
Set the heat mode lock switch (SW5-1) to ON.
1×
1
4
3
2
1
A
1
2
3
4
5
SW5
4
3
2
1
2
OFF
ON
9.5
About cool mode lock
Cool mode lock limits the unit to cool operation. Forced operation
remains possible in cool mode.
Specifications for the connector housing and pins: ST products,
housing VHR‑5N, pin SVH‑21T‑1,1
When cool mode lock is used in combination with the Hybrid for
Multi, these units will NOT operate by the heat pump.
9.5.1
To turn ON cool mode lock
1
Short-circuit pins 3 and 5 of connector S15.
4×
VHR-5N
SVH-21T-1
S15
1 3
5
10
Commissioning
NOTICE
General
commissioning
checklist.
Next
to
the
commissioning instructions in this chapter, a general
commissioning checklist is also available on the Daikin
Business Portal (authentication required).
The general commissioning checklist is complementary to
the instructions in this chapter and can be used as a
guideline and reporting template during the commissioning
and hand-over to the user.
Содержание 2MXM-A
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ...3P600450 6M 2021 12 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...