SiUS121632EA
Outdoor Unit
Specifications
17
60 Hz, 208 - 230 V
Notes:
1.
Max.: for the combination of CTXS, FTXS series indoor units
Min.: for the combination of CDXS, FDXS series indoor units
2. The data are based on the conditions shown in the table below.
Model
3MXL24QMVJU
Cooling
Heating
COP
W/W
—
4.56
EER
Btu/W·h
12.7
—
SEER / HSPF
17.9
12.5
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC63AAXD
Motor Output
W
1,920
Refrigerant Oil
Model
FVC50K
Charge
oz (L)
29.7 (0.9)
Refrigerant
Type
R-410A
Charge
Lbs (kg)
6.17 (2.8)
Airflow Rate
H
cfm
2,094
1,886
M
2,094
1,780
L
1,977
1,006
H
m³/min
59.3
53.4
M
59.3
50.4
L
56.0
28.5
Fan
Type
Propeller
Motor Output
W
58
Running Current
A
H: 0.38 / M: 0.38 / L: 0.33
H: 0.38 / M: 0.33 / L: 0.07
Power Consumption
W
H: 75 / M: 75 / L: 65
H: 75 / M: 65 / L: 14
Starting Current
A
17.5
Dimension (H
×
W
×
D)
in. (mm)
28-15/16
×
34-1/4
×
12-5/8 (735
×
870
×
320)
Packaged Dimension (H
×
W
×
D)
in. (mm)
31-7/8
×
41-3/8
×
17-1/2 (810
×
1,050
×
444)
Weight (Mass)
Lbs (kg)
140 (63)
Gross Weight (Gross Mass)
Lbs (kg)
156 (71)
Sound Pressure Level
dB(A)
52
54
Piping
Connections
Liquid
in. (mm)
φ
1/4
×
3 (
φ
6.4
×
3)
Gas
in. (mm)
φ
3/8
×
1,
φ
1/2
×
2 (
φ
9.5
×
1,
φ
12.7
×
2)
Drain
in. (mm)
φ
5/8 (
φ
15.9)
Heat Insulation
Both Liquid and Gas Pipes
No. of Wiring Connections
3 for Power Supply, 4 for Interunit Wiring (Including Ground Wiring)
Max. Interunit Piping Length
ft (m)
230 (70) (for Total of Each Room)
82 (25) (for One Room)
Amount of Additional Charge of
Refrigerant
oz/ft
(g/m)
0.21 (20) (131-1/4 ft (40 m) or more)
Max. Installation Height Difference
ft (m)
49-1/4 (15) (between Indoor Unit and Outdoor Unit)
24-5/8 (7.5) (between Indoor Units)
Drawing No.
C: 3D101754
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Heating
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
Piping Length
24-5/8 ft (7.5 m)