11
|
Configuration
Installer reference guide
56
2(A)MXM40+50 + 2(A)MXF40+50
R32 Split series
4P600463-3D – 2021.03
11 Configuration
In this chapter
11.1 About ECONO mode prohibition setting
This setting disables the input control signal from the user interface. Use this
setting when you wish to block reception of input controls (cooling/heating) from
indoor unit user interfaces.
11.1.1 To turn on ECONO mode prohibition setting
Prerequisite:
The main power supply MUST be turned off.
1
Remove the top plate of the outdoor unit (2 screws on sides)
2
Remove the electric box cover by sliding it. Be careful not to bend the electric
box hook.
3
Cut the jumper (J23).
a
c
d
e
b
J26
J24
J23
J6
J22
J8
a
Top plate
b
Electric box cover
c
Electric box
d
PCB
e
PCB jumpers