background image

4

www.daikincomfort.com

SS-RKN19

SS-RKN19

www.daikincomfort.com

5

Dimensions — Indoor Units

FTX09NMVJU, FTX12NMVJU

5/16 

(7.9 mm

)

45˚ 45˚

8-7/8 (225 mm)

1-1/16 

(27 mm

)

5-3/16 (132 mm)

ABOUT 14-9/16 (370 mm)

11-1/4 

(285 mm

)

1-7/8 (48 mm)

8-3/4 (223 mm)

30-5/16 (770 mm)

ABOUT 13 (330 mm)

13/16 (20 mm)

4-9/16 (116.5 mm)

9/16 

(14.6 mm

)

1-7/8 (48 mm)

ABOUT 15-3/8 (390 mm)

11-1/4 

(285 mm

)

30-5/16 (770 mm)

7-1/16 

(180 mm

)

21-1/8 (536.6 mm)

1-15/16 (50 mm) MIN

1-3/16 

(30 mm

) MIN

1-15/16 (50 mm) MIN

1-3/4 

(44.5 mm

)

1-7/8 (48 mm)

1-3/4 

(44.5 mm

)

STANDARD LOCATIONS OF WALL HOLES

BOTTOM

65˚

DRAIN HOSE

SIGNAL RECEIVER

AIR FLOW (INDOOR)

REQUIRED SPACE

BLADE ANGLE

UP/DOWN (AUTOMATIC)

FLAPS

INDOOR UNIT ON/OFF SWITCH

RIGHT

COOLING

LEFT

DRY

OPERATION LAMP

50˚

LIQUID PIPE

REAR

50˚

THE MARK (

) SHOWS PIPING DIRECTION

HEATING

SIGNAL TRANSMITTER

TIMER LAMP

FAN

15˚

65˚

GAS PIPE

FRONT PANEL FIXING SCREWS 

(INSIDE)

INCLUDING 

MOUNTING PLATE

GENERAL RATING 

NAME PLATE

TERMINAL BLOCK 

WITH EARTH 

TERMINAL 

(INSIDE)

UP AND DOWN WIND DIRECTION 

CONTROL BLADE MOVABLE RANGE

ROOM TEMP. THERMISTOR 

(INSIDE)

MODEL NAME 

PLATE

WIRELESS REMOTE CONTROLLER 

(ARC480A8)

RIGHT/LEFT 

(MANUAL)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR  PERFORMANCE

)

GAS PIPE 

φ

3/8 (

φ

9.5 mm) CuT 

(THE LENGTH OF PIPE OUTSIDE 

THE UNIT: ABOUT 14-3/16 (360 mm))

LIQUID PIPE 

φ

1/4 (

φ

6.4 mm) CuT 

(THE LENGTH OF PIPE OUTSIDE 

THE UNIT: ABOUT 16-1/8 (410 mm))

DRAIN HOSE 

(CONNECTING PART 

I.D. 

φ

9/16 (

φ

14 mm) 

O.D. 

φ

5/8 (

φ

16  mm) 

(THE HOSE LENGTH OF OUTSIDE 

THE UNIT IS ABOUT 18-1/2 (470 mm))

WALL HOLE FOR EMBEDDED PIPING 

φ

2-9/16 (

φ

65 mm) HOLE

WALL HOLE 

φ

2-9/16 (

φ

65 mm) HOLE

3D091702

FTK24NMVJU

1-3/4 (44.5mm)

1-15/16 (50mm) MIN

5 (126.5mm)

1-7/8 (48mm)

10-3/8 (263mm)

ABOUT 18-1/8 (460mm)

7-1/16 (180mm)

29-3/8 (746mm)

1-3/4 (44.5mm)

10-7/16 (265mm)

11-5/8 (295mm)

11-5/8 

(295mm

)

13/16 (20mm)

1-15/16 (50mm) MIN

ABOUT 17-3/4 (450mm)

9/16 (14.6mm)

1-3/16 (30mm) MIN

39 (990mm)

5/16 (7.9mm)

ABOUT 14-3/8 (365mm)

ABOUT 14-3/16 (360mm)

2-3/8 (60mm)

1/2 

(12mm

)

39 (990mm)

ABOUT 15-3/4 (400mm)

1-7/8 (48mm)

45˚ 45˚

ABOUT 17-5/16 (440mm)

TIMER LAMP

BOTTOM

55˚

70˚

10˚

UP/DOWN (AUTOMATIC)

15˚

INDOOR UNIT ON/OFF SWITCH

GAS PIPE

80˚

AIR FLOW (INDOOR)

REAR

65˚

THE MARK (

) SHOWS PIPING DIRECTION

REQUIRED SPACE

GAS PIPE 

φ

5/8 (

φ

15.9mm) CuT

STANDARD LOCATIONS OF WALL HOLES

BLADE ANGLES

30˚

FLAPS

LIQUID PIPE

SIGNAL TRANSMITTER

LEFT

OPERATION LAMP

MODEL NAME PLATE

25˚

RIGHT/LEFT (MANUAL)

RIGHT

DRAIN HOSE

FAN

COOLING, DRY

SIGNAL RECEIVER

FRONT GRILLE FIXING SCREWS 

(INSIDE)

ROOM TEMP. THERMISTOR 

(INSIDE)

WIRELESS REMOTE CONTROLLER 

(ARC480A9)

UP AND DOWN WIND DIRECTION 

CONTROL BLADE MOVABLE RANGE

)

(

INCLUDING 

MOUNTING PLATE

GENERAL RATING 

NAME PLATE

TERMINAL BLOCK 

WITH EARTH 

TERMINAL 

(INSIDE)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR  PERFORMANCE)

DRAIN HOSE 

(CONNECTING PART 

I.D. 

φ

9/16 (

φ

14mm) 

O.D. 

φ

5/8 (

φ

16mm)

LIQUID PIPE 

φ

1/4 (

φ

6.4mm) CuT

WALL HOLE FOR EMBEDDED PIPING 

φ

3-1/8 (

φ

80mm) HOLE

WALL HOLE 

φ

3-1/8 (

φ

80mm) HOLE

3D091782

Содержание 19 SERIES

Страница 1: ...Mode Powerful Operation Mode Wireless Remote Controller with backlit display Outdoor Unit quiet operation with backlight Auto Changeover Heat Pump only Auto Fan Speed Control Self Diagnostics with dig...

Страница 2: ...l 09 9 000 BTU h 18 18 000 BTU h G Highest Q R 410A Heat Pump 12 12 000 BTU h 24 24 000 BTU h N Standard S High 15 15 000 BTU h __ Mid blank R X _ 09 NM VJ U 1 2 3 4 5 6 7 8 9 10 Unit Type Standard Co...

Страница 3: ...rflow Dry H M L SL CFM 403 328 251 215 413 321 258 219 745 604 470 420 745 604 470 420 Sound Pressure Cooling H M L SL dB A 43 36 30 19 45 37 30 19 49 44 38 33 53 45 39 34 Sound Pressure Heating H M L...

Страница 4: ...8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16 65 mm HOLE...

Страница 5: ...ABOUT 16 1 8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16...

Страница 6: ...m 10 7 16 265mm INCLUDING MOUNTING PLATE 39 990mm THE MARK SHOWS PIPING DIRECTION WIRELESS REMOTE CONTROLLER ARC480A8 3D091779 FTX24NMVJU 1 3 4 44 5mm 1 3 16 30mm MIN 11 5 8 295mm 10 3 8 263mm 29 3 8...

Страница 7: ...AIN OUTLET I D 5 8 15 9mm HOSE FOR CONNECTION WITH DRAIN JOINT SERVICE PORT MANUFACTURER S LABEL C 3D092206 RK18NMVJU RX18NMVJU HANDLE 2 3 4 70 9 16 14 34 1 4 870 OUTDOOR AIR THERMISTOR 1 4 7 1 3 16 3...

Страница 8: ...MINIMUM SPACE FOR AIR PASSAGE unit inch mm 11 7 16 291 3 15 16 100 20 11 16 525 1 15 16 50 1 15 16 50 1 15 16 50 3 15 16 100 3 15 16 100 4 1 8 105 6 1 2 165 13 3 4 350 13 3 4 350 13 3 4 350 6 13 16 1...

Страница 9: ...0 mm ABOUT 13 330 mm ABOUT 15 3 8 390 mm GAS PIPE 3 8 9 5 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 14 3 16 360 mm LIQUID PIPE 1 4 6 4 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 16 1 8 41...

Страница 10: ...Q1L R1T R2T R3T S20 S40 S70 S80 S90 X11A SA1 SWITCHING POWER SUPPLY OVERLOAD PROTECTOR THERMISTOR CONNECTOR SURGE ABSORBER V1 V2 V3 X1M Y1E Y1S Z1C Z2C Z3C ZF VARISTOR TERMINAL BLOCK ELECTRONIC EXPANS...

Страница 11: ...n with chain KKF936A4 KKF936A4 Interface adaptor for DIII NET use KRP928BB2S KRP067A41 KRP928BB2S KRP980B2 Central remote controller DCS302C71 DCS302C71 Unified ON OFF controller DCS301C71 DCS301C71 S...

Страница 12: ...12 www daikincomfort com SS RKN19 Our continuing commitment to quality products may mean a change in specifications without notice 2016 Houston Texas Printed in the USA Notes...

Отзывы: