![Daikin 18000 Btu Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/daikin/18000-btu/18000-btu_service-manual_502253007.webp)
Si002155E
Outdoor Fan / Fan Motor
Removal Procedure
5
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the drip proof
cover.
2
3
Disconnect the
connector [S70].
Release the fan motor
lead wire from the 2
hooks.
[S70]: fan motor
4
Remove the nut, and
then the outdoor fan.
Nut size: M8
When reassembling, align
the mark of the fan rotor
with the D-cut section of the
motor shaft.
Drip proof cover
(R24838)
Fan motor lead wire
Hook
[S70]
(R26183)
Nut
Outdoor fan
D-cut
(R24841)
13 mm
(0.51 inch)