background image

W

ELDING

 R

ESULT

 C

ONTROL

 F

UNCTION

A

DMINISTRATOR

 F

UNCTIONS

C

HAPTER

 

7

7-8

P45 (WARNING judgment time)
Select the time to judge the event as an error in the range from 0 to 100 seconds when the average current/ 
voltage (average per second) during welding is out of the allowable tolerance range.
When the out-of-range state becomes longer than the time specified here, an alarm displays. (

7.2.2.6

-

 

Alarm indication at the time of WARNING detection (Welding Monitor "P45" "P46"))

If "0" is set, WARNING detection will not be performed.

P46 (Operation at the time of WARNING detection)
Select the operation at the time of WARNING detection from 0 to 2.
The set values and operations at the time of WARNING detection are as below.

7.2.2.5

Alarm indication when target is achieved

When any of the number of welding points, wire consumption and total welding time reaches the target 
specified, its corresponding control No. will flash.

7.2.2.6

Alarm indication at the time of WARNING detection (Welding Monitor "P45" 
"P46")

If the average current or average voltage becomes out of the specified range, the difference between the 
average value and the specified value will flash.

Set value

Operation

Alarm indication only. Welding can continue. (Continuous operation is possible)

1

The ongoing welding can continue.
After the welding is finished, next welding cannot start until any key of the operation panel is pressed. 
(Continuous operation is not possible)

2

Welding stops immediately.
Next welding cannot start until any key of the operation panel is pressed. (Continuous operation is not possible)

 • In the right example, the control No. "P20" flashes on the left 

digital meter and the specified value "910" on the right digital 
meter.

 • The display returns to the normal state when any key of the 

operation panel is pressed.

 • If continuous operation is enabled in the setting of the 

operation for the time when the target is achieved, an alarm 
will display every time welding finishes until any key of the 
operation panel is pressed.

<Example> When wire consumption reached the target 
value

 • The right example shows a current error. The control No. 

"P40" flashes on the left digital meter and the difference 
between the average value and specified value "30" on the 
right digital meter, with the "A" LED lighting.

<Example> While welding is conducted with the welding 
current 200A/Current tolerance (+) 10% (= 220A), the 
average current during welding rose to 230A and the 
WARNING judgment time specified in "P45" elapsed.

A

V

r

WARNING

m/min.
sec.

JOB No.

Hz

A

V

r

WARNING

m/min.

sec.

JOB No.

Hz

Содержание OTC Welbee P500L

Страница 1: ...i s i n s t r u c t i o n m a n u a l thoroughly for safe and proper use of the product October 2013 Manual No 1P30137 1 Model WB P500L Welbee Inverter P500L OWNER S MANUAL Pulse MAG MIG Welding powe...

Страница 2: ......

Страница 3: ...nual hereafter referred to as this manual explains the following points for safe use of the product Caution regarding the product Welding operation setting method Daily maintenance cleaning inspection...

Страница 4: ...e that installation operation maintenance of the welding power source and welding machine is performed by a qualified personnel with sufficient knowledge and skills If this manual is lost or damaged i...

Страница 5: ...Product model manufacture year serial number and software version number Refer to the diagram below for product information Attachment location and content of nameplate may vary depending on the purc...

Страница 6: ...ifting lug 3 6 CHAPTER 4 CONNECTION 4 1 Precautions for Connection Procedure and Grounding 4 1 4 2 Connecting the Welding Power Source 4 2 4 2 1 Connection of cable at output side 4 3 4 2 2 Connection...

Страница 7: ...Control Function 7 4 7 2 1 Setting welding result control function 7 4 7 2 2 Details of welding control items 7 5 7 3 Data Backup Utilization of data 7 9 7 3 1 Setting of welding conditions internal...

Страница 8: ...TABLE OF CONTENTS vi MEMO...

Страница 9: ...stand the content before beginning operation The below symbols are categorized by the degree of possible hazard and damage The below symbols are categorized according to the content to be followed 1 2...

Страница 10: ...chine or work areas Only authorized personnel or person with full understanding and experience of the welding machine must perform installation maintenance and repair of welding machine Make sure to a...

Страница 11: ...ource and wait three minutes or more The capacitors may be still charged even after the input power is cut Make sure that there is no charged voltage before starting the work Wear dry insulating glove...

Страница 12: ...or preventive measure from falling due to anoxia apply lifelines such as a safety belt For the welding operation in a narrow space perform the operation with the trained supervisor Periodically inspec...

Страница 13: ...on gas pipe and closed containers such as tanks or drums Performing arc welding on flammable object such as fuel tank may cause explosion Furthermore welding on closed container such as tanks and pipe...

Страница 14: ...ay from the gas discharge port Keep protective cap in place over valve except when gas cylinder is in use or connected for use Do not place the gas cylinder under high temperature Protect compressed g...

Страница 15: ...g by customer is out of the warranty scope When welding or watching a welder work wear face shield with a proper shade of filter See ANSI Z 49 1 listed in PRINCIPAL SAFETY STANDARDS to protect the fac...

Страница 16: ...Electrical Code NFPA Standard 70 from National Fire Protection Association Safe Handling of Compressed Gases in Cylinders CGA Pamphlet P 1 from Compressed Gas Association Code for Safety in Welding an...

Страница 17: ...ted frequency 50 60 Hz Rated input voltage 400 V Input voltage range 400 V 15 Rated input 25 kVA 22 9 kW Rated input current 36A Rated output current DC 500 A Pulse 400 A Rated load voltage DC 39 V Pu...

Страница 18: ...5 Al PURE 1 2 1 6 STANDARD 3 Al Mg 1 0 1 2 1 6 STANDARD 3 Brazing CuSi 0 8 1 0 1 2 STANDARD 3 Brazing CuAl 0 8 1 0 1 2 STANDARD 3 DC LOW SPATTER 4 CO2 MILD STEEL 0 8 1 0 1 2 STANDARD MAG 20 CO2 1 1 M...

Страница 19: ...an those with the following mixing ratios is used 1 1 MAG gas Argon Ar 80 Carbon dioxide CO2 20 1 2 MAG gas Argon Ar 90 Carbon dioxide CO2 10 1 3 MIG gas stainless steel Argon Ar 98 Oxygen O2 2 1 4 MI...

Страница 20: ...it may not only reduce the duty cycle but also result in degradation or burnout of the welding power source The rated duty cycle of the welding power source is the following Operation cycle at duty c...

Страница 21: ...ce No Name Suppliedunit 1 Optional accessories Remarks 1 Gas regulator To be prepared by the customer 2 2 3 Accessory not supplied 2 Wire feeder 3 Welding torch 4 Gas hose 3 m 2 5 Control cable for wi...

Страница 22: ...torch side 2 m 2 7 Power cable for base metal side 2 m 2 8 Shielding gas To be prepared by the customer 2 2 3 Accessory not supplied 9 Digital remote control optional 2 2 4 Optional accessories 10 An...

Страница 23: ...elding torch 3 Gas hose 3 m 2 4 Power cable for base metal side 2 m 2 5 Shielding gas To be prepared by the customer 2 2 3 Accessory not supplied 6 Digital remote control optional 2 7 Analog remote co...

Страница 24: ...by the customer before operating the welding power source Prepare the following No Name Suppliedunit 1 Optional accessories Remarks 1 Welding electrode holder To be prepared by the customer 2 2 3 Acce...

Страница 25: ...available including remote control and voltage detection cable Name Remarks CO2 gas Carbon dioxide CO2 100 MAG gas Argon Ar 80 Carbon dioxide CO2 20 Argon Ar 90 Carbon dioxide CO2 10 MIG gas Argon Ar...

Страница 26: ...tension cable may cause an unstable arc Use extension cables with suitable length Unnecessarily long extension cable may cause an unstable arc No Product name Model 5 m 10 m 15 m 20 m 1 Gas hose BKGG...

Страница 27: ...of the welding power source 2 3 1 Front panel The section explains the front section of the welding power source Socket for wire feeder Socket for analog remote control Output terminal Torch side Outp...

Страница 28: ...on explains the rear section of the welding power source Blind bush for drawing externally connecting wire Cover for external connections Connector for connecting CAN Print circuit board Terminal bloc...

Страница 29: ...eration Setting to an extremely high output voltage may result in damage to the welding power source When the welding power source is used in a humid environment such as construction site or location...

Страница 30: ...ent and partial exhaust facility in welding work area 3 1 2 1 Ventilation equipment When welding is required in tank boiler reaction tower or hold of a ship closed space or any other places of poor ve...

Страница 31: ...20 C Location with an altitude of less than 1000 m Location with an incline of 10 or less Location with no metallic foreign body such as spatter entering the welding power source Installation distance...

Страница 32: ...lding power source Welding cables Do not use an unnecessarily long cable Place a base metal cable and a torch side cable as closely as possible Equipotential bonding Bonding of all metallic objects in...

Страница 33: ...nd floor Do not apply strong shock to the welding power source when placing it on the floor It may cause damage to the welding power source Since large current abruptly flows inside the welding power...

Страница 34: ...ents be sure to observe the following For operation of a crane or hoisting make sure that a qualified personnel operate them with attention to the surrounding area for safety Use the lifting tool such...

Страница 35: ...parts of the welding power source Have a qualified electrical engineer ground the case of the welding power source and base metal or jig electrically connected in accordance with local regulation Make...

Страница 36: ...ource until confirming the completion of connection work Otherwise electric shock may occur Connection of cable at output side 4 2 1 Connection of cable at output side Connection of wire feeder 4 2 2...

Страница 37: ...ighten them in the clockwise direction 2 Connect the power cable for torch side to the output terminal torch side Connect the connectors as same as above Connection for cable at output side is complet...

Страница 38: ...ol cable 10 cores to the socket for the wire feeder Fit the concave part of the connector and convex part of the socket for secure connection and tighten the knurled screws in the clockwise direction...

Страница 39: ...re connection and tighten the knurled screws in the clockwise direction 2 When using the water cooled welding torch connect the water feeding hose and condensing hose of the welding torch to the wire...

Страница 40: ...eeder TIPS Voltage detection cable for base metal side can also be connected to the direct voltage detection terminal for base metal of the welding power source When using the welding power source by...

Страница 41: ...r reducing the influence of inductance noise Wire the voltage detection cable for the base metal away from the cable of base metal For easier handling cut the voltage detection cable for base metal si...

Страница 42: ...tal Connect the connectors as same as above In using the welding power source for TIG welding prepare a welding torch by the customer Contrary to the normal connection the TIG welding requires connect...

Страница 43: ...n them in the clockwise direction 2 Connect the cable for welding electrode holder side to the output terminal torch side Connect the connectors as same as above In using the welding power source for...

Страница 44: ...sure to observe the following points to prevent from suffocation due to gas leakage or explosion Be sure to turn off the shielding gas at the main tap when the welding power source is not in use Secu...

Страница 45: ...ck due to leakage of electricity may occur Be sure to install a switch with fuse or a circuit breaker for motor to the input side of each welding power source Otherwise electric shock and fire due to...

Страница 46: ...the cable of the welding power source to the breaker Capacity of the switch and the rating of fuse and circuit breaker are appropriate 3 1 1 Welding power source equipment Perform grounding for the ca...

Страница 47: ...see 2 2 4 2 Details on extension cables and hoses 7 Cable at torch side BKPDT 6012 10 m 8 Cable at base metal side BKPDT 6012 10 m 9 Gas hose BKGG 0610 10 m 10 Gas regulator To be prepared by the cust...

Страница 48: ...tage detection cable for torch side K5416P00 optional accessory Connect the other end of the voltage detection cable for torch side K5416P00 to the tip of the torch Use the voltage detection cable for...

Страница 49: ...nput Disconnecting the terminals stops output of the welding power source When combining switches use a push lock turn reset switch for preventing accidental reset 5 9 IN EXT1 External input 1 Reserve...

Страница 50: ...rk make sure to cut the input power with the disconnect switch connected to the welding power source and wait three minutes or more In addition do not turn on the primary power until the work is compl...

Страница 51: ...a knife and pass the cable through Process any given blind bush among the several available types 4 Connect the cable to the terminal for external connection Strip the cable cover by 10 to 11 mm from...

Страница 52: ...using the voltage detection cable set the internal function F38 to ON 6 7 1 Setting procedure Details on the internal function F38 6 7 2 26 F38 Arc voltage direct detection switching 4 6 1 Wiring to w...

Страница 53: ...etection cable at the base metal side to the voltage direct detection terminal at the base metal side of the welding power source 1 Check that input power is turned off with the disconnect switch conn...

Страница 54: ...a power feeding brush to the positioner Insulate the power feeding brush from the jig base and connect the voltage detection cable base metal side to the jig base TIPS Before wiring the voltage detec...

Страница 55: ...ilation equipment does not give sufficient performance ensure to use respiratory protective equipment For preventive measure from falling due to anoxia apply lifelines such as a safety belt For the we...

Страница 56: ...rom spatter and spattering dross Wear protective equipment such as protective leather gloves long sleeve clothes leg covers and leather apron Ignoring the above may cause electrical shock and burn Ins...

Страница 57: ...re the adequate shield gas flow rate as follows CO2 MAG gas MIG gas 10 to 25L min 15 to 25L min 11 When the shield gas is mixed each gas pressure should be the same Set pressures of the respective gas...

Страница 58: ...liner take care for the followings If the liner is too long feeding resistance increases resulting in shorter life of wire feeder If the liner is too short feeding failure occurs Handle the gas cylin...

Страница 59: ...s 6 Press the GAS CHECK key The LED of the GAS CHECK key lights off to stop gas check 5 4 Wire Inching This section explains the inching operation feeding operation of the wire 1 Straighten the torch...

Страница 60: ...that the welding conditions are correct 5 5 2 Preventing erroneous operation on operation panel This section explains how to prevent erroneous operation on the operation panel To prevent accidental ch...

Страница 61: ...e right digital meter both in a real time basis This indication is the average value of the output per approximately one second In TIG welding arc start requires contact of the torch electrode with th...

Страница 62: ...just the welding current When the LED of the CURRENT SETTING DISPLAY SWITCH key is off press the CURRENT SETTING DISPLAY SWITCH key to light up the LED In the adjustment by the remote control this ope...

Страница 63: ...ly 5 seconds the display will return to the one showing current voltage in welding Using the internal function F48 enables to increase decrease the welding current by the torch switch operation It is...

Страница 64: ...ischarged 3 After the shield gas is discharged press the GAS CHECK key The LED of the GAS CHECK key lights off to stop gas check 4 Set the flow adjustment knob to SHUT to adjust the shield gas flow ra...

Страница 65: ...he end of welding Voltage INDIVIDUAL 10 0 to 50 0 V 23 5 V Voltage SYNERGY 100 to 100 0 Post flow time 0 to 10 sec 0 4 sec Set the gas discharge time after the welding ends Arc spot time 0 1 to 10 sec...

Страница 66: ...0 s Sets the display time for the current voltage after completion of welding F9 Analog remote control scale 200 350 500 500 A Configures the settings of scale plate of the analog remote control F10 M...

Страница 67: ...0 F31 External input 3 setting 0 F32 External input 4 setting 0 F33 Inhibition ratio display for squeeze detection When F33 is selected the Squeeze detection inhibition ratio is displayed on the right...

Страница 68: ...me by single clicking of the torch switch available when ON is selected in F48 F50 Current increase and decrease by double clicking 50 to 50 0 A Sets current increase decrease volume by double clickin...

Страница 69: ...s the adjustment value of pulse peak time at the LOW side in pulse welding F65 L base current fine adjustment 60 to 60 0 A Sets the adjustment value of base current at the LOW side in pulse welding F6...

Страница 70: ...uence as the set target During the welding the display can be switched to display the value set as the welding condition 7 F function key Sets the internal function of welding power source 6 7 Setting...

Страница 71: ...he LED flashes 6 6 1 Welding mode setting 15 CRATER FILL key Select the crater treatment method or arc spot at the end of welding The LED of the parameter in selection lights up For details of the cra...

Страница 72: ...lding voltage is automatically set according to the set welding current To fine tune welding voltage adjust the synergic fine adjustment knob When the LED of the VOLT ADJUST key is off INDIVIDUAL mode...

Страница 73: ...onditions The welding power source is equipped with the function to register the welding conditions and reads them out for use The number of welding conditions that are able to be registered are 100 a...

Страница 74: ...ns electronic data stored by this function are susceptible to occurrence of static electricity impact repair etc and there is a possibility that the stored contents may be changed or lost BE SURE TO M...

Страница 75: ...setting values are displayed on the left right digital meters in a flashing mode To change the JOB No to register press the SAVE key The display returns to the status described in step 1 To cancel th...

Страница 76: ...he SAVE key depressed together turn ON the power switch The LED of ENTER key flashes Pressing the DISPLAY CHANGE key enables to check the set values of welding conditions welding parameters to read ou...

Страница 77: ...at the same time turn the parameter adjustment knob counterclockwise to display ALL on the right digital meter When ALL is selected the current welding condition set on the operation panel is also del...

Страница 78: ...2 1 2 MILD STEEL 0 8 1 0 1 2 STANDARD MIG 2 O2 1 3 STAINLESS STEEL 0 8 1 0 1 2 STANDARD STAINLESS FERRITE 0 8 1 0 1 2 STANDARD MIG 2 5 CO2 1 4 STAINLESS STEEL 0 8 1 0 1 2 STANDARD STAINLESS FERRITE 0...

Страница 79: ...um material Wire diameter mm Welding method Range of stable welding power source A HARD ALUMINUM A5183 A5336 etc 1 0 DC 60 to 150 DC pulse DC wave pulse 50 to 150 1 2 DC 75 to 250 DC pulse DC wave pul...

Страница 80: ...er gas discharge time welding current voltage The welding parameters are set according to the welding sequence 6 6 2 1 Welding sequence The basic welding sequence is the process of PRE FLOW MAIN CONDI...

Страница 81: ...ed speed In this case refer to 6 7 2 19 F24 Wire feeding speed setting Turn the parameter adjustment knob to set the welding current The set parameter is displayed on the left digital meter TIPS In th...

Страница 82: ...h pulse Arc Spot The pattern of the following combinations and can not be selected Mode Initial condition Description CRATER FILL OFF In the welding process only available process is the main welding...

Страница 83: ...me setting crater standard time setting 6 6 3 1 Crater OFF Select CRATER OFF by the CRATER FILL key In synchronous to the ON OFF operation of the torch switch the welding starts stops 10 no pulse DC P...

Страница 84: ...rch switch should remain depressed and held during the INITIAL and CRATER phrases When selecting CRATER FILL ON no pulse Regardless of the setting by the WELDING METHOD key the machine automatically t...

Страница 85: ...itch should remain depressed and held during the INITIAL and CRATER phrases When selecting CRATER FILL ON no pulse Regardless of the setting by the WELDING METHOD key the machine automatically turns t...

Страница 86: ...s on the nozzle for arc spot see the instruction manual of the torch 6 6 5 Welding voltage adjustment This section explains how to adjust the welding voltage The adjustment of welding voltage can be c...

Страница 87: ...dition TIPS It is likely that good weld can be obtained by adjusting it to hard in low current region and soft in high current region When using an extended cable for the base material side torch side...

Страница 88: ...feeding speed becomes stable and only the unit pulse condition changes Image of welding bead form in the wave frequency TIPS This function is available when DC WAVE PULSE is selected by the WELDING M...

Страница 89: ...complete Press the DISPLAY CHANGE key and select either INITIAL CONDITION MAIN CONDITION or CRATER FILL CONDITION The LED for the selected welding sequence lights up The LED for the WAVE FRQ key light...

Страница 90: ...ns TIPS The internal function is activated at the point when the setting value is changed To change the set values of internal functions ensure that there is no mistake in the function No as well as i...

Страница 91: ...able mode Set to ON for the length of extension cable longer than 30 m The LED of STANDARD starts flashing when setting to ON OFF Standard mode TIPS In using the welding power source in the HIGH mode...

Страница 92: ...circuit the deactivated terminal pins 3 4 of the external connection terminal block TM3 4 1 In the Auto mode voltage to release welding is output for approx 0 2 seconds after the anti stick process T...

Страница 93: ...pe time 0 0 to 10 0 sec 6 7 2 5 F7 Downslope time When the difference between the welding current and crater current is large the wire may plunge into weld pool at the change of the conditions the wir...

Страница 94: ...not stopped According to the use environment such as wires and torches and the customer s judgment criteria adjust the detection level at your discretion 6 7 2 9 F11 Fine adjustment of welding conditi...

Страница 95: ...Sets the operation time of water cooled pump after welding ends When the water cooled welding torch is used the water cooled pump operates to cool the welding torch as the welding ends The operation...

Страница 96: ...wire tip can be arranged to obtain a stable start of the next welding The time and voltage for anti stick process are automatically set to appropriate conditions depending on the welding method wire...

Страница 97: ...tes in a control mode power saving operation due to the temperature detection inside the welding power source This mode is effective in saving power consumption and preventing suction of extra powder...

Страница 98: ...the maximum command voltage is 22 m min Depending on the welding mode the wire feed speed does not always reach 22 m min The minimum wire feed speed is approximately 0 6 to 2 0 m min This depends on t...

Страница 99: ...rt circuit between terminals allows DC welding mode Open circuit between terminals allows DC pulse welding mode Selecting optional DC Wave Pulse beforehand allows DC wave pulse welding mode 6 7 7 WAVE...

Страница 100: ...l of external input terminal to which this function is allocated to has any change again 6 Even after reading out the welding method by this function welding method can be changed either via the front...

Страница 101: ...isplays the inhabitation ratio on the right digital meter Welding operation is available with F33 selected When the welding is unstable the inhabitation ratio may accordingly become unstable When this...

Страница 102: ...ity Sets whether to automatically correct the detection sensitivity of Squeeze ON enables to automatically set the detection sensitivity of Squeeze OFF disables to automatically set the detection sens...

Страница 103: ...wire extension and welding conditions greatly vary by welding section it is recommended to use the machine with this function set to OFF 6 7 2 25 F36 F37 Spatter adjustment P1P P2P Use this function t...

Страница 104: ...t Gain offset Set the adjustment value gain offset when the current display value on the left digital meter is different from the actual current value The current value displayed on the digital meter...

Страница 105: ...he center of welding voltage setting knob To increase the welding voltage turn the knob clockwise and to reduce the welding voltage turn the knob counterclockwise The fine adjustment range for welding...

Страница 106: ...e internal function F45 is set to ON automatically the setting of No crater is selected disabling other welding modes The CRATER FILL key does not work Welding method at crater treatment is the same a...

Страница 107: ...le clicking or double clicking operation should be within 0 3 seconds At the time of transition to crater press the torch switch for at least 0 3 seconds Welding method at crater treatment is the same...

Страница 108: ...F51 Special crater repeat In the sequence of main welding of the CRATER FILL ON REPEATED during start input holding the torch switch operation can switch the welding and crater treatment repeatedly as...

Страница 109: ...rt or 5 Loading welding condition 6 7 2 36 F52 Data type of data log function This function enables to select data to save when using the data log function The patterns of data which can be saved are...

Страница 110: ...er in the pulse condition of the wave pulse welding at HIGH side fine adjustment is available to the standard pulse peak current at HIGH side by setting the adjustment value Example of current wavefor...

Страница 111: ...lue Example of current waveform of wave pulse welding 6 7 2 45 F65 Fine adjustment of L base current Set the adjustment value in the range of 1 5 to 1 5 ms Fine adjustment of unit pulse condition 6 7...

Страница 112: ...e of current waveform of wave pulse welding 6 7 2 46 F66 Adjustment of feed amplitude ratio This function sets the feed amplitude ratio of wire amplitude change of wire feed speed in the wave pulse we...

Страница 113: ...ndition and the crater condition becomes settable in percentage based on the current value of crater condition OFF disables the function 6 7 2 48 F68 Setting of current value initial condition The cur...

Страница 114: ...e welding current is automatically set and fine adjustment is available for the set welding voltage Align the welding voltage adjustment knob to the center mark and adjust the voltage with the positio...

Страница 115: ...ble if the erroneous operation prevention function is disabled NOTE Write down the password on a piece of paper and store it safely The current password will be requested also when you change it If a...

Страница 116: ...ord will be requested Hold the two keys pressed down until Loc is displayed on the left digital meter PAS Loc will be displayed in order Release the keys after Loc is displayed If a password has alrea...

Страница 117: ...ied as password 3 Select the tens place digit and ones place digit in the same manner as the step 2 4 Press the ENTER key Loc flashes on the left digital meter PAS Loc will be displayed in order The h...

Страница 118: ...lding points is achieved Wire consumption P20 0 00 Cumulative wire consumption used in welding kg P21 0 0 to 999 Target wire consumption kg P22 0 0 to 5 Operation at the time when the target wire cons...

Страница 119: ...lue will be cleared according to the P12 setting If continuous operation is enabled the value will be cleared when exceeding 999 and return to 0 P11 Target value of welding points Select the target va...

Страница 120: ...d P21 Target wire consumption Select the target value of wire consumption in the range from 0 to 999 kg When the P20 count value reaches the wire consumption specified here an alarm appears indicating...

Страница 121: ...ints is achieved 7 2 2 1 Number of welding point 7 2 2 4 Welding monitor Average current voltage during welding is monitored When it exceeds the range specified here an alarm displays and the output s...

Страница 122: ...tion Alarm indication only Welding can continue Continuous operation is possible 1 The ongoing welding can continue After the welding is finished next welding cannot start until any key of the operati...

Страница 123: ...right example shows a voltage error The control No P40 flashes on the left digital meter and the difference between the average value and specified value 1 5 on the right digital meter with the A LED...

Страница 124: ...pre_iset Initial current 1 A wld_feed Welding feed speed 0 1 m min pre_vset Initial voltage 0 1 V cre_feed Crater feed speed 0 1 m min pre_uni_vset Initial voltage synergic 1 ant_tim_adj Anti stick t...

Страница 125: ...ata pls_pki_adj Pulse peak current fine adjustment 1 A CreIsetPer reserved pls_pkt_adj Pulse peak time fine adjustment 0 1 ms TsCrickIset Torch switch current adjustment 0 1 OFF ON pls_bsi_adj Base cu...

Страница 126: ...52 is set to 1 detected values of welding current welding voltage and feeding speed and F53 to 1 100 ms TIPS The length of time that can be used for recording depends on the sampling speed If the samp...

Страница 127: ...flash drive TIPS The USB flash drive to be used should be formatted as FAT32 If it is formatted as FAT16 or NTFS reformat it to FAT32 1 Turn on the power switch 2 Insert the USB flash drive to the USB...

Страница 128: ...en by the backup data Make sure of it before overwriting 1 Turn on the power switch 2 Insert the USB flash drive to the USB connector of the operation panel 3 Press the SAVE key The LED of ENTER key f...

Страница 129: ...s in memory and internal function values will return to the default initial setting Turn the parameter adjusting knob further counterclockwise to display the data to import on the right digital meter...

Страница 130: ...y and turn on the power switch The Product No is displayed on the left and right digital meters The display changes every time the F function key is pressed The display order of 5 or later is for manu...

Страница 131: ...en after the input power is cut Make sure that there is no charged voltage before starting the work During maintenance and inspection take an appropriate measure to prevent turning on the input power...

Страница 132: ...rinted document Please note that OTC will not be liable for any alteration or loss of electronic information When cleaning the welding power source do not expose the cooling fan directly to compressed...

Страница 133: ...not grounded electric shock failure malfunction may occur Status of cables Primary power cable for facility side cables for base metal side torch side torch cable voltage detection cable etc Check th...

Страница 134: ...nsumable parts of the welding torch Abnormality in consumable parts can prevent smooth wire introduction Cleaning inside the welding power source Blow with dry compressed air from the front slit venti...

Страница 135: ...and Voltage Test If insulation resistance measurement and withstand voltage test is necessary please contact your dealer When measuring insulation resistance and testing withstand voltage follow the s...

Страница 136: ...AC side and positive output side and the AC side and negative output side respectively Short circuit between TR1 C1 and E1C2 TR1 E1C2 and E2 TR3 C2 and E2 Apply NF After finishing insulation resistanc...

Страница 137: ...s on the left right digital meters The welding power source may stop or may not stop output depending on the type of error code The meanings of 1 and 2 in the table below are as follows 1 When the err...

Страница 138: ...een 340 to 460 V The error code will disappear when the power switch is turned off E 160 The input voltage for primary side fell below the allowable range 2 Check that the input voltage for primary si...

Страница 139: ...cables connecting the wire feeder Check that there is no problem in the wire feeder The error code will disappear when the power switch is turned off E 810 The temperature of the governor circuit exc...

Страница 140: ...rrect Check that the setting of internal functions F29 to F32 is correct 6 7 2 21 F29 to F32 External input terminal setting The external input cables are disconnected short circuited Check that there...

Страница 141: ...tage detection cable is correct There is noise in the voltage detection cable Adjust the arc characteristics to the plus side 12 Wire is not fed no error code is displayed The pressure roll of wire fe...

Страница 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...

Страница 143: ...DR14 100 0188 Diode module DIN60 1 TR1 to 4 100 1750 IGBT module CM300DU 12NFH 4 TR5 to 7 100 2033 IGBT module FZ600R12KP4 3 CT1 4810 030 Current transformer W W03029A ROHS 1 CT2 100 0956 Hall current...

Страница 144: ...Output DC48V PCB1 P30099P00 Printed circuit board P30099P00 1 CHASSIS 1 PCB2 P30086R00 Printed circuit board P30086R00 1 FRONT PANEL PCB3 P30086Q00 Printed circuit board P30086Q00 1 CHASSIS PCB4 P300...

Страница 145: ...Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 2 Reference Drawing This section contains the schematic diagram and the parts layout drawing of the welding power so...

Страница 146: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram P30086Q00 P30086V00 PCB6 Driver P30086V00 P30115M00...

Страница 147: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 P30099P00 CN1 2 13 16 18 26 33 34 36 39 43 45 48 49 51 52 54 56 60 62 Not connected P30088V00 CN2 to 4 8 Not connected P30086T00 CN7 Not connected P300...

Страница 148: ...Lower P30086Q00 P30115M00 P30087Q00 P30099P00 PS1 P30086S00 P30086V00 DR1 P30086V00 P30088V00 P30087T00 P30086T00 SH DR12 13 CT2 CT1 PL1 FM1 FM2 FM3 TM5 NF 6 CON1 7 CON2 7 R19a b L10 FM4 TR6 TR5 TR7...

Страница 149: ...omes poor The wire feeding length is too short The arc length becomes short Spatter is generated The welding voltage is too high The arc length becomes long The bead width becomes wide Penetration and...

Страница 150: ...5 to 20 4 5 4 0 to 4 5 1 2 200 to 250 23 to 26 45 to 55 15 to 20 6 0 5 0 to 6 0 1 2 280 to 300 29 to 32 40 to 50 15 to 20 9 0 6 0 to 8 0 1 2 300 to 350 32 to 34 40 to 45 15 to 20 12 0 10 0 to 12 0 1 2...

Страница 151: ...0 to 25 Back 16 0 4 to 6 1 2 300 to 350 32 to 35 30 to 35 20 to 25 Front 2 300 to 350 32 to 35 30 to 35 20 to 25 Back 1 6 380 to 420 36 to 39 35 to 40 20 to 25 Front 380 to 420 36 to 39 35 to 40 20 to...

Страница 152: ...0 29 50 1 4 330 30 90 1 6 370 33 90 6 1 2 270 29 45 1 4 330 31 80 1 6 380 34 80 7 1 2 280 30 40 1 4 350 32 50 1 6 380 34 65 8 1 2 300 31 30 1 4 350 33 45 1 6 380 34 52 9 1 2 320 32 30 1 4 350 34 40 1...

Страница 153: ...150 26 to 27 60 4 5 5 1 170 26 to 27 40 6 0 6 1 200 27 to 28 40 8 0 8 1 250 29 to 30 35 12 0 10 1 180 to 200 25 to 27 45 2 180 to 200 25 to 28 45 3 180 to 200 25 to 28 45 16 0 12 1 220 to 230 25 to 2...

Страница 154: ...min 6 0 1 170 25 to 26 30 2 180 26 to 27 30 9 0 1 270 29 to 30 30 2 290 30 to 31 30 12 0 1 280 30 to 31 40 2 330 33 to 34 40 19 0 1 300 31 to 32 45 2 300 31 to 32 45 1 340 32 to 33 45 2 280 30 to 31 4...

Страница 155: ...mm Number of oscillation 120 times min Bevel shape Number of layers Current A Voltage V Remarks 1 100 20 to 21 Slight oscillation 2 280 26 to 27 Slight oscillation 3 280 26 to 27 Slight oscillation 4...

Страница 156: ...V Travel speed cm min Wire feeding length mm Gas flow rate L min 1 5 1 2 60 to 80 16 to 18 60 to 80 12 to 15 20 2 0 1 2 70 to 80 17 to 18 40 to 50 15 20 3 0 1 2 80 to 100 17 to 20 40 to 50 15 20 4 0 1...

Страница 157: ...urrent A Voltage V Travel speed cm min Wire feeding length mm Gas flow rate L min 3 0 1 2 120 to 140 20 to 22 60 to 80 15 20 4 0 1 2 150 to 170 22 to 24 60 to 80 15 to 18 20 6 0 1 6 180 to 210 23 to 2...

Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...