6.7.2.40 F62: Fine adjustment of base current
This function allows fine adjustment of the standard base current; by setting the adjustment value, finely
adjusted base current can be obtained.
Set the adjustment value in the range of -60 to 60 A.
Fine adjustment of unit pulse condition (
-
F60: Fine adjustment of pulse peak current, <Fine
adjustment of unit pulse condition>)
6.7.2.41 F63: Fine adjustment of L pulse peak current
This function allows fine adjustment of the standard pulse peak current at LOW side in the pulse
condition of the wave pulse welding; by setting the adjustment value, finely adjusted pulse peak current
at LOW side can be obtained.
Set the adjustment value in the range of -150 to 150 A.
Fine adjustment of unit pulse condition (
-
F60: Fine adjustment of pulse peak current, <Fine
adjustment of unit pulse condition>)
Example of current waveform of wave pulse welding (
F65: Fine adjustment of L base current)
6.7.2.42 F64: Fine adjustment of L pulse peak time
This function allows fine adjustment of the standard pulse peak time at LOW side in the pulse condition
of the wave pulse welding; by setting the adjustment value, finely adjusted pulse peak time at LOW side
can be obtained.
Set the adjustment value in the range of -1.5 to 1.5 ms.
Fine adjustment of unit pulse condition (
-
F60: Fine adjustment of pulse peak current, <Fine
adjustment of unit pulse condition>)
Example of current waveform of wave pulse welding (
F65: Fine adjustment of L base current)
6.7.2.43 F65: Fine adjustment of L base current
This function allows fine adjustment of the standard pulse base current at LOW side in the pulse
condition of the wave pulse welding; by setting the adjustment value, finely adjusted pulse base current
at LOW side can be obtained.
Set the adjustment value in the range of -60 to 60 A.
Fine adjustment of unit pulse condition (
-
F60: Fine adjustment of pulse peak current, <Fine
adjustment of unit pulse condition>)
<Example of current waveform of wave pulse welding>
Pulse condition at HIGH side
Pulse condition at LOW side
Pulse condition at HIGH side
Current value
Time
Pulse peak current at LOW side
Pulse peak current at HIGH side
Base current at HIGH side
Base current at LOW side
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...