3.1.3 Adjusting procedure of the torch
Fig. 3.6 Adjusting procedure of the torch
(1) If the tip gauge end slips out of the reference point of torch gauge in the upward or downward direction,
loosen the 2 pieces of hexagon socket head cap screws (M8×20) that fix the insulating bracket
(L10620B02) onto the L-bracket (L10620B03). Correct the position, moving the insulating bracket
upward or downward, and then fix it firmly by tightening the screws.
(2) If the tip gauge end slips out of the reference point of torch gauge in the frontward or rearward
direction, loosen the 2 hexagon socket head cap screws (M8×25) that fix the mount (L6300B01) onto
the L-bracket (L10620B03). Correct the position, moving the mount frontward or rearward, and then fix
it firmly by tightening the screws.
Loosen the screw (2 pieces) that fixes the
mount, and adjust the torch back and
forth so that the point of tip gauge can
align with the reference point.
Reference point
Tip gauge
Loosen the screw (2 pieces) that fixes the insulating
bracket, and adjust the torch up and down so that the
point of tip gauge can align with the reference point.
Insulating bracket
(
L10620B02
)
Mount
(
L6300B01
)
Upward
Downward
Loosen the screw that fixes the Nozzle holder ASSY,
and adjust the torch right and left so that the point of
tip gauge can align with the reference point.
L-bracket
(
L10620B03
)
Nozzle holder Assy
(
L10602C
)
Hood
(L10602B02)
Feeding cable
(L10601D)
Backward Forward
Right
Left
Содержание OTC RT3500S