D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
144
The internal function setting data will be output below the JOB Nos. (registration Nos.)
T I P S
•
It is not possible to separately save the welding condition data recorded in memory and the
internal function setting data. Both of the data will always be written in the
"P*****_DAIHEN_OTC_WELDING_PARAMETER.CSV" file.
•
When importing the backup data to the welding power source, both or either of the data
above can be imported at one time.
"ALL": Welding condition data recorded in Internal function setting data
"1": Welding condition data recorded in memory
"2": Internal function setting data
7.4.2
Simplified data log function
The welding status can be checked on a computer by sampling the data during welding and backing them up in the USB
memory. Only three of the following data can be sampled. Adding to this, the "Heat input" will be displayed in column E.
The data types/sampling speed should be specified in the internal function F52/F53 (data log function).
(
Simplified data log will be created below the "DAIHEN_OTC_WELBEE\DAT\DAT00001" folder. A csv file will be
created per welding.
When DAIHEN_OTC_WELBEE\DAT\DAT00001 folder is already existing, "DAT00002" folder will be created below the
"DAIHEN_OTC_WELBEE\DAT" folder and folder for the consecutive number will per created for each simplified data
log.
ctrl
Sequence information
(*1)
exp_ctrl
Extended control
information
−
wmode_H
Process information 1
(*2)
HiSpdPlsAdj
Adjustment value of pulse
auto-adjustment
−
wmode_L
Process information 2
(*2)
dummy1
〜
6
(reserved)
−
pre_feed
Start feed speed
0.1 (m/min)
chksum
Checksum
Checksum
data
wld_feed
Welding feed speed
0.1 (m/min)
−
−
−
*1: 2T and other information is recorded.
*2: Wire diameter, material, shield gas and other process information is recorded.
*3: Information of welding parameter table is recorded.
•
Welding current set value
•
Welding voltage set value
•
Wire feeding speed set value
•
Welding current actual value
•
Welding voltage actual value
•
Wire feeding speed actual value
Item
Description
Unit Item
Description
Unit
Function setting data
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...